| Electronic Components Datasheet Search |
|
MAX1978 Datasheet(PDF) 17 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1978 Datasheet(HTML) 17 Page - Maxim Integrated Products |
|
17 / 20 page ![]() Shutdown Control Drive SHDN low to place the MAX1978/MAX1979 in a power-saving shutdown mode. When the MAX1978/ MAX1979 are in shutdown, the TEC is off (VOS1 and VOS2 decay to GND) and input supply current lowers to 2mA (typ). ITEC Output ITEC is a status output that provides a voltage propor- tional to the actual TEC current. ITEC = REF when TEC current is zero. The transfer function for the ITEC output: VITEC = 1.50 + 8 ✕ (VOS1 - VCS) Use ITEC to monitor the cooling or heating current through the TEC. The maximum capacitance that ITEC can drive is 100pF. Applications Information The MAX1978/MAX1979 drive a thermoelectric cooler inside a thermal-control loop. TEC drive polarity and power are regulated to maintain a stable control tem- perature based on temperature information read from a thermistor, or from other temperature-measuring devices. Carefully selected external components can achieve 0.001°C temperature stability. The MAX1978/ MAX1979 provide precision amplifiers and an integra- tor amplifier to implement the thermal-control loop (Figures 1 and 2). Connecting and Compensating the Thermal-Control Loop Typically, the thermal loop consists of an error amplifier and proportional integral derivative controller (PID) (Figure 4). The thermal response of the TEC module must be understood before compensating the thermal loop. In particular, TECs generally have stronger heat- ing capacity than cooling capacity because of the effects of waste heat. Consider this point when analyz- ing the TEC response. Analysis of the TEC using a signal analyzer can ease compensation calculations. Most TECs can be crudely modeled as a two-pole system. The second pole poten- tially creates an oscillatory condition because of the associated 180° phase shift. A dominant pole compen- sation scheme is not practical because the crossover frequency (the point of the Bode plot where the gain is zero dB) must be below the TEC’s first pole, often as low as 0.02Hz. This requires an excessively large inte- grator capacitor and results in slow loop-transient response. A better approach is to use a PID controller, where two additional zeros are used to cancel the TEC and integrator poles. Adequate phase margin can be achieved near the frequency of the TEC’s second pole when using a PID controller. The following is an exam- ple of the compensation procedure using a PID con- troller. Figure 6 details a two-pole transfer function of a typical TEC module. This Bode plot can be generated with a signal analyzer driving the CTLI input of the MAX1978/MAX1979, while plotting the thermistor volt- age from the module. For the example module, the two poles are at 0.02Hz and 1Hz. The first step in compensating the control loop involves selecting components R3 and C2 for highest DC gain. Film capacitors provide the lowest leakage but can be large. Ceramic capacitors are a good compromise between low leakage and small size. Tantalum and electrolytic capacitors have the highest leakage and generally are not suitable for this application. The inte- grating capacitor, C2, and R3 (Figure 4) set the first zero (fz1). The specific application dictates where the first zero should be set. Choosing a very low frequency results in a very large value capacitor. Set the first zero frequency to no more than 8 times the frequency of the lowest TEC pole. Setting the frequency more than 8 times the lowest pole results in the phase falling below -135° and may cause instability in the system. For this example, C2 = 10µF. Resistor R3 then sets the zero at 0.16Hz using the following equation: This yields a value of R3 = 99.47k Ω. For our example, use 100k Ω. Next, adjust the gain for a crossover frequency for max- imum phase margin near the TEC’s second pole. From Figure 6, the TEC bode plot, approximately 30dB of gain is needed to move the 0dB crossover point up to 1.5Hz. The error amplifier provides a fixed gain of 50, or approximately 34dB. Therefore, the integrator needs to provide -4dB of gain at 1.5Hz. C1 and R3 set the gain at the crossover frequency. C A C RfC 1 1 2 23 = +× × π fz CR 1 1 22 3 = ×× π Integrated Temperature Controllers for Peltier Modules ______________________________________________________________________________________ 17 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |