| Electronic Components Datasheet Search |
|
AXP209 Datasheet(PDF) 30 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
AXP209 Datasheet(HTML) 30 Page - List of Unclassifed Manufacturers |
|
30 / 45 page ![]() AXP209 Enhanced single Cell Li-Battery and Power System Management IC 5D [3: 0] VBUS Current ADC Data Low 4 Bit R 5E [7: 0] AXP209 Internal temperature monitoring ADC Data High 8 Bit R 5F [3: 0] AXP209 Internal temperature monitoring ADC Data Low 4 Bit R 62 [7: 0] TS Input ADC Data High 8 Bit, the default monitor battery temperature R 63 [3: 0] TS Input ADC Data Low 4 Bit, the default monitor battery temperature R 64 [7: 0] GPIO0 Voltage ADC Data High 8 Bit R 65 [3: 0] GPIO0 Voltage ADC Data Low 4 Bit R 66 [7: 0] GPIO1 Voltage ADC Data High 8 Bit R 67 [3: 0] GPIO1 Voltage ADC Data Low 4 Bit R 70 [7: 0] High instantaneous power battery 8 Bit R 71 [7: 0] Instantaneous power in the battery 8 Bit R 72 [7: 0] Instantaneous battery power is low 8 Bit R 78 [7: 0] Battery voltage is high 8 Bit R 79 [3: 0] Battery voltage is low 4 Bit R 7A [7: 0] Battery charge current high 8 Bit R 7B [3: 0] Battery charge current low 4 Bit R 7C [7: 0] Battery discharge current high 8 Bit R 7D [4: 0] Battery discharge current low 5 Bit R 7E [7: 0] System IPSOUT High Voltage 8 Bit R 7F [3: 0] System IPSOUT Voltage Low 4 Bit R Note: The battery-powered power calculation method Pbat = 2 * Register values * Voltage LSB * Current LSB / 1000. Where the voltage LSB is 1.1mV; Current LSB is 0.5mA, Calculated in units of mW. Address Register Description R / W Default value B0 Coulomb charging the battery meter data register[31:24] R / W 00H B1 Coulomb charging the battery meter data register[23:16] R / W 00H B2 Coulomb charging the battery meter data register[15: 8] R / W 00H B3 Coulomb charging the battery meter data register[7: 0] R / W 00H B4 Coulomb gauge battery discharge data register[31:24] R / W 00H B5 Coulomb gauge battery discharge data register[23:16] R / W 00H B6 Coulomb gauge battery discharge data register[15: 8] R / W 00H B7 Coulomb gauge battery discharge data register[7: 0] R / W 00H B8 Coulomb gauge and encryption module control register R / W 00H B9 Power measurement result register R / W 00H Coulomb calculation method: C= 65536 * current LSB *(charge coulomb counter value - discharge coulomb counter value) / 3600 / ADC sample rate. Refer to REG84H setting for ADC sample rate;the current LSB is 0.5mA;unit of the calculation result is mAh. Confidential Page 30/45 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |