15 / 23 page ![]() Preliminary Datasheet TLE6288 R Vp2 Page 15 13.01.2003 8.2 SPI Diagnostics: As soon as a fault occurs for longer than the fault filtering time, the fault information is latched into the diagnosis register (and the Fault pin will change from high to low state). A new error on the same channel will over-write the old error report. Serial data out pin (SO) is in a high impedance state when CS is high. If CS receives a LOW signal, all diagnosis bits can be shifted out serially. If the sent com- mand was valid the rising edge of CS will reset the diagnosis registers (except the channel OT flag) and restart the fault filtering time. In case of an invalid command the device will ignore the data bits and the diagnosis register will not be reset at the rising CS edge. Figure 1: Two bits per channel diagnostic feedback plus two overtemperature flags For Full Diagnosis there are two diagnostic bits per channel configured as shown in Figure 1. Diagnosis bit0 and bit1 are always set to 1. Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal function. Overload, Shorted Load or Overtemperature: HL is set when the current limitation gets active, i.e. there is a overload, short to supply or overtemperature condition. The second reason for this bit combi- nation is overtemperature of the corresponding channel. Open load: LH is set when open load is detected (in off state of the channel) Switch Bypassed: Short to GND : in lowside configuration LL is set when this condition is detected Short to Battery : in highside configuration LL is set when this condition is detected Channel Overtemperature Flag: In case of overtemperature in any output channel in on state the overtemperature Flag in the SPI diagnosis register is set (change bit 3 from 0 to 1). This Bit can be used to distinguish between Overload and Overtemperature (both HL combination) and is reset by switching OFF/ON the affected channel. In addition the DIAG6 / Ovtertemp pin is set low (if configured as Overtemp.Flag). IC Overtemperature Flag: When the IC logic tremperature exceeds typ.170° the non-latching IC Overtemperature Flag will be set in the SPI diagnosis register(change bit 2 from 0 to 1). In addition the DIAG6 / Ovtertemp pin is set low (if configured as Overtemp.Flag). 8.3 SPI Commands, Values and Parameters: Diagnostic Serial Data Out SO HH Normal function HL Overload, Shorted Load or Overtemperature LH Open Load LL Switch Bypassed Ch.6 Ch.5 Ch.4 Ch.3 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB Ch.2 Ch.1 LSB Channel Overtem- perature Flag IC Overtem- perature Flag Bit0 and Bit1 is always 1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |