8 / 15 page ![]() Ver 0.2 Preliminary Dec 11, 2001 TEL: 886-3-5788833 http://www.gmt.com.tw 8 G771 Global Mixed-mode Technology Inc. Interfacing to µPs with Bi-directional Reset Pins A µP with bi-directional reset pins (such as the Mo- torola 68HC11 series) can connect to the G771 reset output. If, for example, the G771 RESET output is asserted high and the µP wants to pull it low, indeterminate logic levels may result. To correct this, connect a 4.7k Ω resistor between the G771 RESET output and the µP reset I/O (Figure 4). Buffer the G771 RESET output to other system components. Benefits of Highly Accurate Reset Threshold Most µP supervisor Ics have reset threshold voltages between 5% and 10% below the value of nominal sup- ply voltages. This ensures a reset will not occur within 5% of the nominal supply, but will occur when the sup- ply is 10% below nominal. When using Ics rated at only the nominal supply ±5% this leaves a zone of uncertainty where the supply is between 5% and 10% low, and where the reset may or may not be asserted. The G771 use highly accurate circuitry to ensure that reset is asserted close to the 5% limit, and long before the supply has declined to 10% below nominal. Fig 3. RESET Valid to VCC = Ground Circuit SMBus Digital Interface From a software perspective, the G771 appears as a set of byte-wide registers that contain temperature data, alarm threshold values, fan speed data, or con- trol bits, A standard SMBus 2-wire serial interface is used to read temperature data and write control bits and alarm threshold data. Each A/D and fan control channel within the device responds to the same SMBus slave address for normal reads and writes. The G771 employs four standard SMBus protocols: Write Byte, Read Byte, Send Byte, and Receive Byte (Figure 5). The shorter Receive Byte protocol allows quicker transfers, provided that the correct data regis- ter was previously selected by a Read Byte instruction. Use caution with the shorter protocols in multi-master systems, since a second master could over-write the command byte without informing the first master. The temperature data format is 7bits plus sign in twos-complement form for each channel, with each data bit representing 1°C (Table3), transmitted MSB first. Measurements are offset by +1/2°C to minimize internal rounding errors; for example, +99.6°C is re- ported as +100°C. Fig 4. Interfacing to µPs with Bi-directional Reset I/O V CC G771 RESET GND R1 100k V CC G771 RESET GND R1 100k V CC G771 RESET GND BUFFER RESET GND V CC µP 4.7k BUFFERED RESET TO OTHER SYSTEM COMPONENTS V CC G771 RESET GND BUFFER RESET GND V CC µP 4.7k BUFFERED RESET TO OTHER SYSTEM COMPONENTS |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |