| Electronic Components Datasheet Search |
|
G771 Datasheet(PDF) 10 Page - Global Mixed-mode Technology Inc |
|
|
|||||||||||||||||||||||||||||
G771 Datasheet(HTML) 10 Page - Global Mixed-mode Technology Inc |
|
10 / 15 page ![]() Ver: 0.2 Preliminary Dec 11, 2001 TEL: 886-3-5788833 http://www.gmt.com.tw 10 G771 Global Mixed-mode Technology Inc. If the remote channel is shorted (DXP to DXN or DXP to GND), the ADC reads 0000 0000 so as not to trip either the THIGH or TLOW alarms at their POR set- tings. In applications that are never subjected to 0°C in normal operation, a 0000 0000 result can be checked to indicate a fault condition in which DXP is acciden- tally short circuited. Similarly, if DXP is short circuited to VCC, the ADC reads +127°C for both channels, and the device alarms. ALERT Interrupts The ALERT interrupt output signal is latched and can only be cleared by reading the Alert Response ad- dress. Interrupts are generated in response to THIGH and TLOW comparisons and when the remote diode is disconnected (for continuity fault detection). The in- terrupt does not halt automatic conversions; new tem- perature data continues to be available over the SMBus interface after ALERT is asserted. The interrupt output rupt output pin is open-drain so that device can share a common interrupt line. The interrupt rate can never exceed the conversion rate. The interface responds to the SMBus Alert Response address, an interrupt pointer return-address feature (see Alert Response Address section). Prior to taking corrective action, always check to ensure that an in- terrupt is valid by reading the current temperature. Alert Response Address The SMBus Alert Response interrupt pointer provides quick fault identification for simple slave devices that lack the complex, expensive logic needed to be a bus master. Upon receiving an ALERT interrupt signal, the host master can broadcast a Receive Byte transmission to the Alert Response slave address (0001 100). Then any slave device that generated an interrupt attempts to identify itself by putting its own address on the bus. Table 4. Command-Byte Bit Assignments REGISTER COMMAND POR STATE FUNCTION RRTE2 00h 0000 0000b Read 2nd remote temperature: returns latest temperature RRTE1 01h 0000 0000b Read 1st remote temperature: returns latest temperature RSL 02h N/A Read status byte (flags, busy signal) RCL 03h 0000 0000b Read configuration byte RCRA 04h 0000 0010b Read conversion rate byte RRHI2 05h 0111 1111b (127) Read 2nd remote THIGH limit RRLS2 06h 1100 1001b(-55) Read 2nd remote TLOW limit RRHI1 07h 0111 1111b (127) Read 1st remote THIGH limit RRLS1 08h 1100 1001b (-55) Read 1st remote TLOW limit WCA 09h N/A Write configuration byte WCRW 0Ah N/A Write conversion rate byte WRHA2 0Bh N/A Write 2nd remote THIGH limit WRLN2 0Ch N/A Write 2nd remote TLOW limit WRHA1 0Dh N/A Write 1st remote THIGH limit WRLN1 0Eh N/A Write 1st remote TLOW limit OSHT 0Fh N/A One-shot command (use send-byte format) TCRIT1 35h 0110 1100b (108) Critical temperature for 1 st remote temperaure sensor TCRIT2 36h 0101 1000b (88) Critical temperature for 2 nd remote temperaure sensor The Alert Response can activate several different slave devices simultaneously, similar to the SMBus General Call. If more than one slave attempts to respond, bus arbitration rules apply, and the device with the lower address code wins. The losing device does not generate an acknowledge and continues to hold the ALERT line low until serviced (implies that the host interrupt input is level sensitive). Successful reading of the alert response address clears the interrupt latch. Command Byte Functions The 8-bit command byte register (Table 4) is the mas- ter index that points to the various other registers within the G771. The register's POR state is 0000 0000, so that a Receive Byte transmission (a protocol that lacks the command byte) that occurs immediately after POR returns the current local temperature data. The one-shot command immediately forces a new conversion cycle to begin. In software standby mode ( RUN /STOP bit = high), a new conversion is begun, after which the device returns to standby mode. If a conversion is in progress when a one-shot command is received in auto-convert mode (RUN/STOP bit = low) between conversions, a new conversion begins, the conversion rate timer is reset, and the next automatic conversion takes place after a full delay elapses. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |