| Electronic Components Datasheet Search |
|
G771 Datasheet(PDF) 9 Page - Global Mixed-mode Technology Inc |
|
|
|||||||||||||||||||||||||||||
G771 Datasheet(HTML) 9 Page - Global Mixed-mode Technology Inc |
|
9 / 15 page ![]() Ver 0.2 Preliminary Dec 11, 2001 TEL: 886-3-5788833 http://www.gmt.com.tw 9 G771 Global Mixed-mode Technology Inc. Write Byte Format S Address WR ACK Command ACK DATA ACK P 7 bits 8 bits 8 bits 1 Slave Address: equivalent to chip-select line of a 3-wire interface Command Byte: selects, which register you, are writing to Data Byte: data goes into the register set by the command byte (to set thresholds, configuration masks, and sampling rate) Read Byte Format S Address WR ACK Command ACK S Address RD ACK DATA /// P 7 bits 8 bits 7 bits 8 bits Slave Address: equivalent to chip- select line Command Byte: selects, which register you, are reading from Slave Address: repeated due to change in data-flow direction Data byte: reads from the register set by the command byte Send Byte Format S Address WR ACK Command ACK P 7 bits 8 bits Command Byte: sends command with no data usually used for one-shot command Receive Byte Format S Address RD ACK Data /// P 7 bits 8 bits Data Byte: reads data from the register commanded by the last Read Byte or Write Byte transmission; also used for SMBus Alert Response return address S = Start condition Shaded = Slave transmission P = Stop condition /// = Not acknowledged Fig 5. SMBus Protocols Table 3. Data Format (Twos-Complement) DIGITAL OUTPUT DATA BITS TEMP. ( °°°°C) ROUND TEMP. ( °°°°C) SIGN MSB LSB +130.00 +127 0 111 1111 +127.00 +127 0 111 1111 +126.50 +127 0 111 1111 +126.00 +126 0 111 1110 +25.25 +25 0 001 1001 +0.50 +1 0 000 0001 +0.25 +0 0 000 0000 +0.00 +0 0 000 0000 -0.25 +0 0 000 0000 -0.50 +0 0 000 0000 -0.75 -1 1 111 1111 -1.00 -1 1 111 1111 -25.00 -25 1 110 0111 -25.50 -25 1 110 0110 -54.75 -55 1 100 1001 -55.00 -55 1 100 1001 -65.00 -65 1 011 1111 -70.00 -65 1 011 1111 Alarm Threshold Registers Four registers store alarm threshold data, with high-temperature (THIGH) and low-temperature (TLOW) registers for each A/D channel. If either measured temperature equals or exceeds the corre- sponding alarm threshold value, an ALERT interrupt is asserted. The power-on-reset (POR) state of both THIGH regis- ters is full scale (0111 1111, or +127°C). The POR state of both TLOW registers is 1100 1001 or -55°C. Diode Fault Alarm There is a continuity fault detector at DXP that detects whether the remote diode has an open-circuit condi- tion. At the beginning of each conversion, the diode fault is checked, and the status byte is updated. This fault detector is a simple voltage detector; if DXP rises above VCC - 1V (typical) due to the diode current source, a fault is detected. Note that the diode fault isn't checked until a conversion is initiated, so imme- diately after power-on reset the status byte indicates no fault is present, even if the diode path is broken. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |