Back Button IMS15 Datasheet HTML 4Page - Bel Fuse Inc. IMS15 Datasheet HTML 5Page - Bel Fuse Inc. IMS15 Datasheet HTML 6Page - Bel Fuse Inc. IMS15 Datasheet HTML 7Page - Bel Fuse Inc. IMS15 Datasheet HTML 8Page - Bel Fuse Inc. IMS15 Datasheet HTML 9Page - Bel Fuse Inc. IMS15 Datasheet HTML 10Page - Bel Fuse Inc. IMS15 Datasheet HTML 11Page - Bel Fuse Inc. IMS15 Datasheet HTML 12Page - Bel Fuse Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 19 page
background image
IMX15, IMY15 , IMS15 Series Data Sheet
15 Watt DC-DC Converters
BCD20008-G Rev AE, 25-Aug-2017
Page 8 of 19
MELCHER
The Power Partners.
Electrical Output Data
We recommend connecting an external 1 µF ceramic capacitor across the output pins.
General conditions:
– TA = 25 °C, unless TC is specified
– Shutdown pin and Trim or R pin left open-circuit (not connected)
Table 7a: Output data for single-output models -03-8RG 1 and 05-8RG 1
Output
3.3 V
5.1 V
Unit
Characteristics
Conditions
min
typ
max
min
typ
max
Vo
Output voltage
Vi nom
3.25
3.35
5.05
5.15
V
Io = 0.5 Io nom
Io nom
Output current
20IMX Vi min to Vi max
4.5
3.5
A
40IMX /110IMY
4.5
3.5
Io L
Current limit 2
Vi nom, TC = 25 °C
6.0
4.6
Vo ≤ 93% Vo nom
∆V
o
Line/load regulation
Vi min to Vi max,
±0.5
±0.5
%
(0.1 to 1) Io nom
Vo
Output voltage noise
Vi min to Vi max
4
100
100
mVpp
Io = I o nom
5
60
60
Vo L
Output overvoltage limit. 3
115
130
115
130
%
Co ext
Admissible capacitive load
0
4000 6
0
4000 6
µF
Vo d
Dynamic
Voltage deviat.
Vi nom
±250
±250
mV
to d
load
Recovery time
Io nom ↔ 1/2 Io nom
11
ms
regulation
IEC/EN 61204
α
Vo
Temperature coefficient
Vi min to Vi max
±0.02
±0.02
%/K
∆V
o /∆TC
(0.1 to 1) Io nom
1
SR Models -8RG (synchr. rectifier) have a minimum case and operating temperature of –25 °C. If the revision is BA (or later), it is –40 °C.
2
The current limit is primary side controlled. In the event of a sustained overload condition the thermal protection may cause the converter
to shut down (restart after cooling down).
3
The overvoltage protection is via a primary side second regulation loop. It is not tracking with R control.
4
BW = 20 MHz
5
Measured with a probe according to EN 61204
6
Co ext is limited to 3000 µF, if Vi >125 V or TA < 25 °C



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com