| Electronic Components Datasheet Search |
|
AD7298 Datasheet(PDF) 20 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7298 Datasheet(HTML) 20 Page - Analog Devices |
|
20 / 25 page ![]() AD7298 Rev. B | Page 19 of 24 POWER-DOWN MODES The AD7298 has a number of power conservation modes of operation that are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for different application requirements. The power-down modes of operation of the AD7298 are controlled by the power-down (PPD) bit in the control register and the PD/RST pin on the device. When power supplies are first applied to the AD7298, care should be taken to ensure that the part is placed in the required mode of operation Normal Mode Normal mode is intended for the fastest throughput rate performance because the user does not have to be concerned about any power-up times because the AD7298 remains fully powered on at all times. Figure 28 shows the general diagram of operation of the AD7298 in this mode. The conversion is initiated on the falling edge of CS and the track-and-hold enters hold mode. On the 14th SCLK falling edge, the track-and-hold returns to track mode and starts acquiring the analog input, as described in the section. The data presented to the AD7298 on the DIN line during the first 16 clock cycles of the data transfer are loaded into the control register (provided the WRITE bit is 1). The part remains fully powered up in normal mode at the end of the conversion as long as the PPD bit is set to 0 in the write transfer during that conversion. Serial Interface To ensure continued operation in normal mode, the PPD bit should be loaded with 0 on every data write operation. Sixteen serial clock cycles are required to complete the conversion and access the conversion result. For specified performance, the throughput rate should not exceed 1 MSPS. Once a conversion is complete and the CS has returned high, a minimum of the quiet time, tQUIET, must elapse before bringing CS low again to initiate another conversion and access the previous conver- sion result. CS SCLK DOUT DIN 11 DATA WRITTEN TO CONTROL REGISTER IF REQUIRED 4 CHANNEL ADDRESS BITS + CONVERSION RESULT 6 Figure 28. Normal Mode Operation Partial Power-Down Mode In this mode, part of the internal circuitry on the AD7298 is powered down. The AD7298 enters partial power-down on the CS rising edge once the current serial write operation containing 16 SCLK clock cycles is completed. To enter partial power-down, the PPD bit in the control register should be set to 1 on the last required read transfer from the AD7298. Once in partial power-down mode, the AD7298 transmits all 1s on the DOUT pin if CS is toggled low. If the averaging feature for the temperature sensor is enabled in the control register, the averaging is reset once the device enters partial power-down mode. The AD7298 remains in partial power-down until the power- down bit, PPD, in the control register is changed to a logic level zero (0). The AD7298 begins powering up on the rising edge of CS following the write to the control register disabling the power-down bit. Once tQUIET has elapsed, a full 16-SCLK write to the control register must be completed to update its content with the desired channel configuration for the subsequent conversion. A valid conversion is then initiated on the next CS falling edge. Because the AD7298 has one cycle latency, the first conversion result after exiting partial power-down mode is available in the fourth serial transfer, as shown in Figure 29. The first cycle updates the PPD bit, the second cycle updates the configuration and Channel ID bits, the third completes the conversion, and the fourth accesses the DOUT valid result. The use of this mode enables a reduction in the overall power consumption of the device. CS SCLK DOUT DIN 112 16 1 16 1 16 INVALID DATA INVALID DATA WRITE TO THE CONTROL REGISTER, SELECT CH1, PPD = 0 PART IS IN PARTIAL POWER DOWN WRITE TO CONTROL REGISTER, PPD = 0. CONTROL REGISTER CONFIGURED TO POWER UP DEVICE. SELECT ANALOG INPUT CHANNELS FOR CONVERSION. THE NEXT CYCLE WILL CONVERT THE FIRST CHANNEL PROGRAMMED IN THIS WRITE OPERATION. PART BEGINS TO POWER UP ON CS RISING EDGE. THE PART IS FULLY POWERED UP ONCE THE WRITE TO THE CONTROL REGISTER IS COMPLETED. AD7298 CONVERTING CHANNEL 1 NEXT CYCLE HAS CHANNEL 1 RESULT AVAILABLE FOR READING. tQUIET tQUIET NO WRITE TO CONTROL REGISTER Figure 29. Partial Power-Down Mode of Operation |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |