4 / 16 page ![]() 4/16 sames RM2102DSE http://www.sames.co.za PRELIMINARY The connections are made as is shown in figure 4. Also see Table 1. The optical-isolated pulse output is taken to the + and - terminals on the meter-box. A mechanical counter can also be connected to J21 on the PCB in place of the stepper motor counter that is currently connected to J20 on the PCB. Please take note that the meter is referenced to live, and care must be taken when connecting test equipment to the meter. The PM2102DP meter is equipped with several solderable selectors , which will allow the user / meter manufacturer to set the meter up to their own specifications. Table 2 describes the various jumper options. This table should be used in conjunction with figure 5, which will make it easier to locate the jumper in question. 1 Figure 5: Solderable selector positions and default setup. This default setup enables fast mode output, with the pulse stability circuitry enabled, for the measurement of bi- directional DESIGN EXAMPLES Selection Of R1, R2 And R0 For Different Rated Conditions DF_LED DF_MO Please note that the MOTOR and PULSE outputs are related to each other, thus changing the one will change the other. The following equations and tables state the basic pulse constants and motor constants obtainable with the PM2102DP meter. The Output pulse equation is: LED p/kWh = 1160p/sec x (1/DF_LED) x [3600 / ((Vnom x IMAX) / 1000)] And the motor constant equation is: MOTOR p/kWh = LED p/kWh / DF MO where dividing factors and are described in Table 3 (R2, R1 and R0 are input pins for SA2102D). Example 1 Rated voltage: 220V Rated current: 80A Sensing element: SHUNT (80A, 50mV, 625µ ) Pulse constant: 800 imp/kWh Motor constant: 100 imp/kWh Calculate R15 and R16: R15 = R16 = (I / 16µA) x R / 2 = 80A / 16µA x 625µ / 2. = 1.5625 k A standard value of 1k6 is chosen. The pulse constant is derived from the equation below: LED p/kWh = 1160p/sec x (1 / DF_LED) x [3600/((Vnom x Imax)/1000)] = 1160 p/sec x (1 / DF_LED) x [3600 / (220 x 80) / 1000] 800 = 1160 p/sec x (1 / DF_LED ) x 204.54 1 / DF_LED = 0.0033717 DF_LED = 296 MOTOR p/kWh = LED p/kWh / DF_MO 100 = 800 / DF_MO DF_MO = 8 W LSH W W Table 1: External connector descriptions Name Function Description Live Current In Neutral Current Out Live Neutral Optical-isolated output. Connect to measurement equipment 1 2 3 4 + and - Notes 1. Solderable selectors are two pads that can be connected together by means of solder to act as a jumper. SA2102D J22 J11 J19 J3 C8 J4 J5 J6 J7 CNF FAST MAINS J1 DIRO/DIRI SHUNT J2 SAMES R0 R1 R2 SO VDD VDD VSS VSS |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |