| Electronic Components Datasheet Search |
|
SA2102DSA Datasheet(PDF) 6 Page - Sames |
|
|
|||||||||||||||||||||||||||||
SA2102DSA Datasheet(HTML) 6 Page - Sames |
|
6 / 16 page ![]() 6/16 sames RM2102DSE http://www.sames.co.za PRELIMINARY R2 R1 R0 Rated Condition (V / I) LED Output (p/kWh) MON, MOP (p/kWh) 0 0 0 220/10A 6400 100 0 0 1 220/20A 3200 100 0 1 0 220/40A 1600 100 0 1 1 220/80A 800 100 1 0 0 220/6A 6400 100 1 0 1 220/30A 3200 100 1 1 0 220/60A 1600 100 Thus using table 3, it is seen that the closest value could be R0 = 1, R1 = 1 and R2 = 0 Rated voltage: 220V Rated current: 20A Sensing element: SHUNT (80A, 50mV, 625µ ) Pulse constant: 3200 imp/kWh Motor constant: 100 imp/kWh Calculate R15 and R16: R15 = R16 = (I / 16µA) x R / 2 = 20A / 16µA x 625µ / 2. = 390.625 A standard value of 390 is chosen. The pulse constant is derived from the equation below: MOTOR p/kWh = LED p/kWh / DF_MO 100 = 3200 / DF_MO DF_MO = 32 Thus using table 3, it is seen that the closest value could be R0 = 1, R1 = 0, and R2 = 0. In the above table a “1” implies that the selector is connected to V . Example 2 DD W W W W LSH LED p/kWh = 1160p/sec x (1 / DF_LED) x [3600/((Vnom x Imax)/1000)] = 1160 p/sec x (1 / DF_LED) x[3600 / (220 x 20) / 1000] 3200 = 1160 p/sec x (1 / DF_LED ) x 818.18 1 / DF_LED = 0,003371 DF_LED = 296 Table 3: DF_LED and DF_MO factors for SA2102D R2 0 0 0 0 1 1 1 R1 0 0 1 1 0 0 1 R0 0 1 0 1 0 1 0 DF_LED 322 322 322 322 536 214 214 DF_MO 64 32 16 8 64 16 8 CALIBRATING THE METER The meter is calibrated by means of a resistive ladder connected to the voltage input of the SA2102D. The 8 resistor values are available to choose the maximum calibration range, while the 8 jumpers provide 256 possible combinations for precise tuning. Soldering a particular selector closed will short-circuit the corresponding resistor. This will in effect remove the resistor from the voltage divider, and thus provide a higher voltage at the input of R18, which is connected to the voltage input of the device. The ideal is to have 14V at the input of R18 (1M ) that supply a 14µA current to the device. It is possible to over-drive this setting by plus or minus 20% and this will enable or disable the resistors in the resistor ladder to achieve the precise PULSE and MOTOR constants required. RM S W Standard meter constants for various rated conditions The following table list the most common and frequently used pulse and motor constants for different rated conditions. Table 4 serves as an easy reference for meter manufacturers, and constants not listed can be calculated by using the equations provided in the previous examples. Table 4: Different meter constants |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |