  FNP600 Datasheet HTML 1Page - Bel Fuse Inc. FNP600 Datasheet HTML 2Page - Bel Fuse Inc. FNP600 Datasheet HTML 3Page - Bel Fuse Inc. FNP600 Datasheet HTML 4Page - Bel Fuse Inc. FNP600 Datasheet HTML 5Page - Bel Fuse Inc. FNP600 Datasheet HTML 6Page - Bel Fuse Inc. FNP600 Datasheet HTML 7Page - Bel Fuse Inc. FNP600 Datasheet HTML 8Page - Bel Fuse Inc. FNP600 Datasheet HTML 9Page - Bel Fuse Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 12 page
background image
FNP600/850/1000
© 2015 Bel Power Solutions, Inc.
866.513.2839
tech.support@psbel.com
BCD20034-G_AE
PARAMETER
CONDITIONS/DESCRIPTION
Static
Includes static information such as: part number and revision level, output rating, serial number, date
code, and manufacturing location.
Status
(Logic 1 or 0)
Power Supply OK.
AC Input OK.
DC Output OK.
Power Supply Seated.
Overtemperature.
Overcurrent.
Fan OK.
Real-Time Monitoring
Output voltage (main output) 0.1V LSD.
Output current (main output) 0.1A LSD.
Time in service.
Control Signals
Enable for main output.
Output voltage to: (0.01V resolution on 12V
supplies; 0.05V resolution on all 48V supplies).
Fan speed level.
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL60950-1 (UL), CSA C22.2 60950-1 (cUL), EN60950-1
(TUV), IEC60950-1 and CE (LVD)
Electromagnetic Interference
FCC CFR title 47 Part 15
Sub-Part B,
Conducted:
EN55022/CISPR 22.
Radiated:
B
A
Class
Harmonics
Per IEC61000-3-2.
A
Class
Voltage Fluctuation and Flicker
Per IEC61000-3-3.
Pass
ESD Susceptibility
Per EN61000-4-2, Level 4. Criterion B
8
.
kV
Radiated Susceptibility
Per EN 61000-4-3, Level 3. Criterion A
10
.
V/M
EFT/Burst
Per EN 61000-4-4, Level 4. Criterion B
±4
.
kV
Input Transient Protection
Per EN 61000-4-5, Class 3. Criterion B
Line-to-Line:
Line-to-Ground:
1
2
.
kV
RF Conducted Disturbances
Per EN 61000-4-6, Level 3. Criterion A
10
.
V
Voltage Interruptions
Per EN 61000-4-11, performance criterion B 30%.
Per EN 61000-4-11, performance criterion C 60%.
Per EN 61000-4-11, performance criterion C 95%.
10
100
5
.
ms
ms
Sec
Voltage Sag Immunity
Per SEMI F47-0999 > 100 VAC.
No output voltage interruption.
.
Leakage Current
Per EN60950-1.
At 240 VAC:
3.5
mA



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com