Back Button IC-MSC Datasheet HTML 27Page - IC-Haus GmbH IC-MSC Datasheet HTML 28Page - IC-Haus GmbH IC-MSC Datasheet HTML 29Page - IC-Haus GmbH IC-MSC Datasheet HTML 30Page - IC-Haus GmbH IC-MSC Datasheet HTML 31Page - IC-Haus GmbH IC-MSC Datasheet HTML 32Page - IC-Haus GmbH IC-MSC Datasheet HTML 33Page - IC-Haus GmbH IC-MSC Datasheet HTML 34Page - IC-Haus GmbH IC-MSC Datasheet HTML 35Page - IC-Haus GmbH  
Zoom Inzoom in Zoom Outzoom out
 32 / 35 page
background image
prel
imin
ary
prel
imin
ary
iC-MSC SIN/COS SIGNAL CONDITIONER
WITH FAIL-SAFE 1 Vpp LINE DRIVER
Rev A2, Page 32/35
Driver Shutdown
PDMODE
Addr. 0x18, bit 6
Code
Function
0
Driver shutdown terminates with the error event
1
Permanent driver shutdown until cycling power
Table 53: Driver Activation
Error Protocol
Out of the errors enabled by EMASKE both the first
error (under ERR1) and last error (under ERR2) which
occur after the iC-MSC is powered up are stored in the
EEPROM.
The EEPROM also has a memory area in which all oc-
curring errors can be stored (ERR3). Only the fact that
an error has occurred can be recorded, with no infor-
mation as to the time and count of appearance of that
error given. Error recording can be used to statistically
evaluate the causes of system failure, for example.
ERR1
Addr. 0x20, bit 6:0
ERR2
Addr. 0x22, bit 0; Addr. 0x21, bit 7:2
ERR3
Addr. 0x23, bit 2:0; Addr. 0x22, bit 7:4
Bit
Error Event
6:0
Assignment according to EMASKE
Code
Function
0
No event
1
Registered error event
Table 54: Error Protocol
REVERSE POLARITY PROTECTION
The line drivers in iC-MSC are protected against re-
verse polarity and short-circuiting.
A defective or
wrongly connected device cable cause damage neither
to iC-MSC nor to the components protected against
reverse polarity by VDDS and GNDS.
The following pins are also reverse polarity protected:
PC, NC, PS, NS, PZ, NZ, ERR, VDD, GND and ACO
(as long as GNDS is only loaded relative to VDDS). The
maximum voltage difference between the pins should
not exceed 6 V (8 V for pin ERR).
Note: If iC-MSC detects reverse polarity on power up,
the line drivers will not be enabled.
If the state of reverse polarity is resolved, iC-MSC re-
boots from the EEPROM and enables the line drivers.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com