Back Button IC-MSC Datasheet HTML 27Page - IC-Haus GmbH IC-MSC Datasheet HTML 28Page - IC-Haus GmbH IC-MSC Datasheet HTML 29Page - IC-Haus GmbH IC-MSC Datasheet HTML 30Page - IC-Haus GmbH IC-MSC Datasheet HTML 31Page - IC-Haus GmbH IC-MSC Datasheet HTML 32Page - IC-Haus GmbH IC-MSC Datasheet HTML 33Page - IC-Haus GmbH IC-MSC Datasheet HTML 34Page - IC-Haus GmbH IC-MSC Datasheet HTML 35Page - IC-Haus GmbH  
Zoom Inzoom in Zoom Outzoom out
 33 / 35 page
background image
prel
imin
ary
prel
imin
ary
iC-MSC SIN/COS SIGNAL CONDITIONER
WITH FAIL-SAFE 1 Vpp LINE DRIVER
Rev A2, Page 33/35
APPLICATION HINTS
Connecting MR sensor bridges for safety-related applications
For safety-related applications iC-MSC requires an external overvoltage protection of supply VDD (Zener diode
with fuse, for instance) and external pull-down resistors at the inputs X3 to X6 towards GNDS (of up to 100 kΩ).
-
+
-
+
-
+
X3
X4
X5
X6
PS
PZ
SCL
SDA
VDD
VDDS
X1
X2
GND
GNDS
NC
NS
NZ
PC
ACO
ERR
SCL
SDA
VN
VP
MR0
R2
100kΩ
100kΩ
R4
100kΩ
R1
R3
100kΩ
100nF
C1
MR1
MR2
R6
2.2kΩ
R5
2.2kΩ
+5V
ERR
100Ω
RL
RL
RL
100Ω
100Ω
TVS diode array
0V
I2C
LEVEL
SIGNAL
INPUT COS
CONTROL
INPUT ZERO
INPUT SIN
24xx
iC-MSC
F1
5.6V
D1
100nF
C2
Figure 11: Example circuit for safety-related applications.
PLC Operation
There are PLCs with a remote sense supply which re-
quire more time for the voltage control to settle. At the
same time the PLC inputs can have high-impedance re-
sistances relative to an internal, negative supply voltage
which define the input potential for open inputs.
In this instance iC-MSC’s reverse polarity protection
feature can be activated as the outputs are tristate
during the start phase and the resistances in the PLC
determine the pin potential. During the start phase
neither the supply VDD nor the output pins, which are
also monitored, must fall to below ground potential (pin
GND), otherwise the device will not be configured and
the outputs remain permanently set to tristate.
Note: In order to ensure that iC-MSC starts with the
PLCs mentioned above pull-up resistors can be used
in the encoder. Values of 100 kΩ are usually sufficient;
it is, however, recommended that PLC specifications
be specifically referred to here.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com