| Electronic Components Datasheet Search |
|
BMA020 Datasheet(PDF) 44 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMA020 Datasheet(HTML) 44 Page - Bosch Sensortec GmbH |
|
44 / 50 page ![]() Data sheet BMA020 Digital, triaxial acceleration sensor Bosch Sensortec Rev. 1.2 Page 44 30 May 2008 © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. output can be generated and trigger the system master. The wake-up mode is used for ultra-low power applications where inertial factors can be an indicator to change the activity mode of the system. The following table shows values calculated for the average current consumption during the wake-up mode of the BMA020. The power consumption in wake-up mode is dependent on the duration of the interrupt algorithm (number of data acquisitions) and the bandwidth (for more details on setting of the bandwidth please refer to chapter 3.1.3). Table 13: Average current consumption in self wake-up mode using high-g or low-g interrupt Current consumption during BMA020 wake-up mode [µA] (depending on bandwidth, calculated using typical values) Pause [ms] (@ 1,500Hz) (@ 750Hz) (@375Hz) (@190Hz) (@100Hz) (@50Hz) (@25Hz) 20 16.3 21,8 31.8 48.4 71.6 102.9 134.7 80 5.1 6.6 9.7 15.4 25.0 42.3 68.4 360 1.9 2.3 3.0 4.4 6.9 12.0 21.3 2,560 1.1 1.2 1.3 1.5 1.9 2.6 4.1 Durations of the pause values can vary for about ±30% due to the accuracy of the ultra-low- power oscillator implemented within the sensor. For estimating the typical current consumption in wake-up mode the following formula can be applied: i_self_wake_up = (i_DD · t_active + i_DDsbm · wake-up-pause) / (t_active + wake-up-pause) With the approximation: t_active = 1ms + 0.333ms · (4 ⋅ 750 / bandwidth) + 0.333ms · (1500 / bandwidth) · n With the following parameters: i_DD Current in normal mode i_DDsm Current in sleep mode wake_up_pause Setting of wake-up pause n number of data points in any-motion logic (n=0 for high-g threshold and low-g threshold interrupt, n=3 for any-motion logic) Bandwidth Setting of bandwidth (750-25 Hz), for 1500Hz t_active = 1ms + 0.333ms · (1500/bandwidth) · n |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |