Electronic Components Datasheet Search
  English  ▼

X  

LTC3882 Datasheet(PDF) 24 Page - Analog Devices

Part # LTC3882
Description  60V Dual Output Step-Up Controller with Digital Power System Management
PDF  116 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AD [Analog Devices]
Direct Link  http://www.analog.com
Logo AD - Analog Devices

LTC3882 Datasheet(HTML) 24 Page - Analog Devices

Back Button LTC3882 Datasheet HTML 20Page - Analog Devices LTC3882 Datasheet HTML 21Page - Analog Devices LTC3882 Datasheet HTML 22Page - Analog Devices LTC3882 Datasheet HTML 23Page - Analog Devices LTC3882 Datasheet HTML 24Page - Analog Devices LTC3882 Datasheet HTML 25Page - Analog Devices LTC3882 Datasheet HTML 26Page - Analog Devices LTC3882 Datasheet HTML 27Page - Analog Devices LTC3882 Datasheet HTML 28Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 116 page
background image
LTC7880
24
Rev 0
For more information www.analog.com
OPERATION
Any fault or warning event will cause the ALERT pin to
assert low unless the fault or warning is masked by the
SMBALERT_MASK. The pin will remain asserted low
until the CLEAR_FAULTS command is issued, the device
acknowledges the ARA, the fault bit is written to a 1, bias
power is cycled or a MFR_RESET command is issued, the
RUN pin is toggled OFF/ON, or the part is commanded
OFF/ON via PMBus.
Output and input fault event handling is controlled by the
corresponding fault response byte as specified in Tables 7
to 11. Shutdown from these types of faults can either be
retry or latched. For retry, the faults are not latched, so if
the fault condition is not present after the retry interval has
elapsed, a new soft-start is attempted. If the fault persists,
the controller will continue to retry. The retry interval is
specified by the MFR_RETRY_DELAY command and pre-
vents damage to the regulator components by repetitive
power cycling, assuming the fault condition itself is not
immediately destructive. The MFR_RETRY_DELAY must
be greater than 120ms. It can not exceed 83.88 seconds.
Status Registers and ALERT Masking
Figure 4 summarizes the internal LTC7880 status reg-
isters accessible by PMBus command. These contain
indication of various faults, warnings and other important
operating conditions. As shown, the STATUS_BYTE and
STATUS_WORD commands also summarize contents of
other status registers. Refer to PMBus Command Details
for specific information.
NONE OF THE ABOVE in STATUS_BYTE indicates that
one or more of the bits in the most-significant byte of
STATUS_WORD are also set.
In general, any asserted bit in a STATUS_x register also
pulls the ALERT pin low.
The SMBALERT_MASK command can be used to prevent
the LTC7880 from asserting ALERT low with some minor
exceptions. STATUS_ events that cause ALERT to be as-
serted low can be masked by setting the corresponding
STATUS_ bit in the SMBALERT_MASK command. These
masksettingsapplytoSTATUS_WORDandSTATUS_BYTE
in the same fashion as the status bits themselves. For
example, if ALERT is masked for all bits in Channel 0
STATUS_VOUT, then ALERT is effectively masked for the
VOUT bit in STATUS_WORD for PAGE 0.
The BUSY bit in STATUS_BYTE also asserts ALERT low
and can be masked. This bit can be set as a result of vari-
ousinternalinteractionswithPMBuscommunication.This
fault occurs when a command is received that cannot be
safely executed with one or both channels enabled. As
discussed in Application Information, BUSY faults can
be avoided by polling MFR_COMMON before executing
some commands.
If the user’s PMBus system can tolerate clock stretching,
most, if not all, BUSY faults can be avoided by enabling
CLOCKSTRETCHINGbysettingbit1oftheMFR_CONFIG_
ALL to a value of 1.
If masked faults occur immediately after power up, ALERT
may still be pulled low because there has not been time
to retrieve all of the programmed masking information
from EEPROM.
Status information contained in MFR_COMMON and
MFR_PADS can be used to further debug or clarify the
contents of STATUS_BYTE or STATUS_WORD as shown,
but the contents of these registers may not affect the state
of the ALERT pin and may not directly influence bits in
STATUS_BYTE or STATUS_WORD.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com