Back Button AD74115BCPZ Datasheet HTML 58Page - Analog Devices AD74115BCPZ Datasheet HTML 59Page - Analog Devices AD74115BCPZ Datasheet HTML 60Page - Analog Devices AD74115BCPZ Datasheet HTML 61Page - Analog Devices AD74115BCPZ Datasheet HTML 62Page - Analog Devices AD74115BCPZ Datasheet HTML 63Page - Analog Devices AD74115BCPZ Datasheet HTML 64Page - Analog Devices AD74115BCPZ Datasheet HTML 65Page - Analog Devices AD74115BCPZ Datasheet HTML 66Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 62 / 103 page
background image
Data Sheet
AD74115
THEORY OF OPERATION
analog.com
Rev. 0 | 62 of 103
Digital Linear Slew Rate Control
The digital linear slew rate control feature of the AD74115 controls
the rate at which the output transitions to the new value. This slew
rate control feature is available for both the current and voltage
outputs.
When the slew rate control feature is disabled, the output value
transitions at a rate limited by the output drive circuitry and the
attached load.
To reduce the slew rate, enable the digital slew rate control feature
via the OUTPUT_CONFIG register.
After the digital slew rate control feature is enabled, the output
steps digitally at a rate defined by the user in the OUTPUT_CON-
FIG register. The SLEW_LIN_STEP bits dictate the number of
codes per increment, and the SLEW_LIN_RATE bits dictate the
rate at which the codes are updated. Table 30 shows the typical
programmable slew rates for a zero-scale to full-scale (or full-scale
to zero-scale) DAC update that is available on the AD74115.
The DAC_ACTIVE register can monitor the progress of slewing to
a target DAC code. This register contains the code that is currently
loaded to the DAC.
If the digital slewing is disabled before the end code in the
DAC_CODE register is reached, the value remains at the DAC_AC-
TIVE value and does not ramp to the end code.
Table 30. Programmable Slew Times for a Zero-Scale to Full-Scale Code Update
Update Slew Rate, Programmable via SLEW_LIN_RATE Bits (kHz)
Step Size (% of Full-Scale DAC Voltage), Programmable via SLEW_LIN_STEP Bits1
0.8%
1.5%
6.1%
22.2%
4
31.3 ms
16.7 ms
4.1 ms
1.1 ms
64
2.0 ms
1.0 ms
256 μs
70.4 μs
150
833 μs
444 μs
109 μs
30.0 μs
240
521 μs
277 μs
68.3 μs
18.8 μs
1 These are theoretical values. The final slew rate is limited by the CLOAD value.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com