Back Button AD74115BCPZ Datasheet HTML 12Page - Analog Devices AD74115BCPZ Datasheet HTML 13Page - Analog Devices AD74115BCPZ Datasheet HTML 14Page - Analog Devices AD74115BCPZ Datasheet HTML 15Page - Analog Devices AD74115BCPZ Datasheet HTML 16Page - Analog Devices AD74115BCPZ Datasheet HTML 17Page - Analog Devices AD74115BCPZ Datasheet HTML 18Page - Analog Devices AD74115BCPZ Datasheet HTML 19Page - Analog Devices AD74115BCPZ Datasheet HTML 20Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 103 page
background image
Data Sheet
AD74115
SPECIFICATIONS
analog.com
Rev. 0 | 16 of 103
Table 13. General Specifications (Continued)
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
POWER SUPPLY MONITORS
Falling thresholds
AVDD Threshold
5.7
V
AVSS Threshold
−1.6
V
AVCC Threshold
4.1
V
DVCC Threshold
2.0
V
ALDO1V8 Threshold
1.3
V
DO_VDD Threshold
9.5
V
POWER REQUIREMENTS
Supply Voltages1
AVDD
6
24
28.8
V
Headroom requirements must be met for specific
application
AVSS
−18
−15
−2.5
V
Footroom requirements must be met for specific
application
DVCC
2.7
3.3
5.5
V
AVCC
4.5
5.0
5.5
V
DO_VDD
10
35
V
Supply Quiescent Currents
AVDD Current
3.5
3.9
4.3
mA
Configured in voltage or current output mode, no load
current
3.1
3.8
4.8
mA
Configured in any RTD or any analog or digital input
mode, no load current
2.8
3.2
3.6
mA
Configured in digital output mode
AVSS Current
3.4
4.3
5.1
mA
Configured in any RTD or any analog or digital input
mode
DVCC Current
0.7
1.4
1.7
mA
Configured in any RTD or any analog or digital input
mode
AVCC Current
4.0
5.0
6.2
mA
Configured in any RTD or any analog or digital input
mode
DO_VDD Current
50
μA
Configured in high Impedance mode
400
600
μA
Configured in any digital output mode
CONFIGURATION TIMING
Device Power-Up Time1
1
ms
After all supplies are powered up
Device Reset Time1
1
ms
Time taken for device reset and calibration memory
upload to complete hardware or software reset events
after the device is powered up (see Table 14 for pulse
width specifications)
Use Case Switch Time1
200
μs
Time in use case before changing to another use
case
Channel Function Enable Time
200
µs
Wait time after the CH_FUNC_SETUP register is
programmed before new DAC codes can be loaded
1 Guaranteed by design and characterization.
2 If the charge pump is enabled, connect the CP_OUT pin to AVSS and ensure that there is no other source on AVSS.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com