Back Button TM320LC203 Datasheet HTML 12Page - Texas Instruments TM320LC203 Datasheet HTML 13Page - Texas Instruments TM320LC203 Datasheet HTML 14Page - Texas Instruments TM320LC203 Datasheet HTML 15Page - Texas Instruments TM320LC203 Datasheet HTML 16Page - Texas Instruments TM320LC203 Datasheet HTML 17Page - Texas Instruments TM320LC203 Datasheet HTML 18Page - Texas Instruments TM320LC203 Datasheet HTML 19Page - Texas Instruments TM320LC203 Datasheet HTML 20Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 83 page
background image
TMS320C203, TMS320C209, TMS320LC203
DIGITAL SIGNAL PROCESSORS
SPRS025B – JUNE 1995 – REVISED AUGUST 1998
16
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251–1443
multiplier (continued)
Two multiply/accumulate instructions (MAC and MACD) fully utilize the computational bandwidth of the
multiplier, allowing both operands to be processed simultaneously. The data for these operations can be
transferred to the multiplier each cycle by way of the program and data buses. This facilitates single-cycle
multiply/accumulates when used with the repeat (RPT) instruction. In these instructions, the coefficient
addresses are generated by program address generation (PAGEN), while the data addresses are generated
by data-address generation (DAGEN). This allows the repeated instruction to sequentially access the values
from the coefficient table and step through the data in any of the indirect addressing modes.
The MACD instruction, when repeated, supports filter constructs (weighted running averages) so that as the
sum-of-products is executed, the sample data is shifted in memory to make room for the next sample and to
throw away the oldest sample.
The MPYU instruction performs an unsigned multiplication, which greatly facilitates extended-precision
arithmetic operations. The unsigned contents of TREG are multiplied by the unsigned contents of the addressed
data memory location, with the result placed in PREG. This allows the operands of greater than 16 bits to be
broken down into 16-bit words and processed separately to generate products of greater than 32 bits. The
SQRA (square/add) and SQRS (square/subtract) instructions pass the same value to both inputs of the
multiplier for squaring a data-memory value.
After the multiplication of two 16-bit numbers, the 32-bit product is loaded into the 32-bit product register
(PREG). The product from PREG can be transferred to the CALU or to data memory by way of the SPH (store
product-high register) and the SPL (store product-low register) instructions. Note: the transfer of PREG to either
the CALU or data memory passes through the product-scaling shifter (PSCALE) and is therefore affected by
the product-shift mode defined by PM bits in the ST1 register. This is important when saving PREG in an
interrupt-service-routine-context save as the PSCALE shift effects cannot be modeled in the restore operation.
PREG can be cleared by executing the MPY #0 instruction. The product register can be restored by loading the
saved low half into TREG and executing the MPY #1 instruction. The high half is then loaded using the LPH
instruction.
central arithmetic logic unit
The TMS320C2xx central arithmetic logic unit (CALU) implements a wide range of arithmetic and logical
functions, the majority of which execute in a single clock cycle. This arithmetic logic unit (ALU) is referred to as
“central” to differentiate it from a second ALU used for indirect-address-generation (called the ARAU). Once an
operation is performed in the CALU, the result is transferred to the accumulator (ACC), where additional
operations, such as shifting, can occur. Data that is input to the CALU can be scaled by the input data-scaling
shifter (ISCALE) when coming from one of the data buses (DRDB or PRDB) or scaled by PSCALE when coming
from the multiplier.
The CALU is a general-purpose arithmetic/logic unit that operates on 16-bit words taken from data memory or
derived from immediate instructions. In addition to the usual arithmetic instructions, the CALU can perform
Boolean operations, facilitating the bit manipulation ability required for a high-speed controller. One input to the
CALU is always provided from the accumulator, and the other input can be provided from the product register
(PREG) of the multiplier or the output of the scaling shifter (that has been read from data memory or from the
ACC). After the CALU has performed the arithmetic or logical operation, the result is stored in the accumulator.
The TMS320C2xx supports floating-point operations for applications requiring a large dynamic range. The
NORM (normalization) instruction is used to normalize fixed-point numbers contained in the accumulator by
performing left shifts. The four bits of the TREG define a variable shift through the scaling shifter for the
LACT/ADDT/SUBT (load/add to/subtract from accumulator with shift specified by TREG) instructions. These
instructions are useful in floating-point arithmetic where a number needs to be denormalized—that is,
floating-point to fixed-point conversion. They are also useful in the execution of an automatic gain control (AGC)
going into a filter. The BITT (bit-test) instruction provides testing of a single bit of a word in data memory based
on the value contained in the four LSBs of TREG.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com