20 / 44 page ![]() Table 7-4. Configuration Register Field Descriptions (continued) Bit Field Type Reset Description 11-9 AVG R/W 000b Sets the number of ADC conversion results to be averaged. The read- back registers are updated after averaging is completed. 000b = 1 001b = 4 010b = 16 011b = 64 100b = 128 101b = 256 110b = 512 111b = 1024 8-6 VBUSCT R/W 100b Sets the conversion time of the VBUS measurement 000b = 140 µs 001b = 204 µs 010b = 332 µs 011b = 588 µs 100b = 1100 µs 101b = 2116 µs 110b = 4156 µs 111b = 8244 µs 5-3 VSHCT R/W 100b Sets the conversion time of the SHUNT measurement 000b = 140 µs 001b = 204 µs 010b = 332 µs 011b = 588 µs 100b = 1100 µs 101b = 2116 µs 110b = 4156 µs 111b = 8244 µs 2-0 MODE R/W 111b Operating mode, modes can be selected to operate the device either in Shutdown mode, continuous mode or triggered mode. The mode also allows user to select mux settings to set continuous or triggered mode on bus voltage, shunt voltage measurement. 000b = Shutdown 001b = Shunt Voltage triggered, single shot 010b = Bus Voltage triggered, single shot 011b = Shunt voltage and Bus voltage triggered, single shot 100b = Shutdown 101b = Continuous Shunt voltage 110b = Continuous Bus voltage 111b = Continuous Shunt and Bus voltage Return to the Summary Table. 7.6.1.2 Shunt Voltage Register (Address = 1h) [reset = 0000h] The Shunt Voltage Register stores the current shunt voltage reading, VSHUNT and is show in Table 7-5. Negative numbers are represented in two's complement format. Generate the two's complement of a negative number by complementing the absolute value binary number and adding 1. An MSB = '1' denotes a negative number. Example: For a value of VSHUNT = –80 mV: 1. Take the absolute value: 80 mV 2. Translate this number to a whole decimal number (80 mV ÷ 2.5 µV) = 32000 3. Convert this number to binary = 0111 1101 0000 0000 4. Complement the binary result = 1000 0010 1111 1111 INA236 SBOSA81C – MAY 2021 – REVISED DECEMBER 2022 www.ti.com 20 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: INA236 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |