| Electronic Components Datasheet Search |
|
LEG Datasheet(PDF) 13 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
LEG Datasheet(HTML) 13 Page - Sensata Technologies, Inc. |
|
13 / 24 page ![]() OPERATING CHARACTERISTICS Inrush Pulse Tolerance The following table provides a comparison of inrush pulse tolerance with and without the inertial delay feature for each of the 50/60Hz delays. Pulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. The table at left provides a guide to determine if the inertia delay feature is required. Consult factory for further assistance. TYPICAL RESISTANCE / IMPEDANCE Current Ratings (Amps) Impedance DC (ohms) AC, 50/60Hz (ohms) AC, 400Hz (ohms) 51, 52, 53, 59 61, 62, 63, 69 41, 42, 43, 49 0.200 45.8 28.5 71.94 1.00 1.38 1.10 2.85 2.00 0.371 0.29 0.76 5.00 0.055 0.051 0.12 10.0 0.017 0.016 0.032 20.0 0.006 0.006 0.010 30.0 0.003 0.004 0.006 50.0 0.0019 0.0018 — DCR and Impedance based on 100% rated current applied and stabilized for a minimum of one hour. Tolerance .05-2.5 amperes ± 20%: 2.6 -20 amperes ± 25%, 21-50 amperes ± 50%. Consult factory for special values and for coil impedance of delays not shown. PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS Delay 100% 125% 150% 200% 400% 600% 800% 1000% 41 No Trip May Trip .500 to 8.0 .150 to 1.9 .020 to .40 .006 to .25 .004 to .1 .004 to .05 42 No Trip May Trip 5 to 70 2.2 to 25 .40 to 5.0 .012 to 2 .006 to .2 .006 to .15 43 No Trip May Trip 35 to 350 12 to 120 1.5 to 20 .012 to 2.2 .01 to .22 .01 to .1 49 No Trip May Trip .100 Max .050 Max .020 Max .020 Max .020 Max .020 Max 51* No Trip .500 to 6.5 .300 to 3.0 .100 to 1.2 .031 to .500 .011 to .25 .004 to .1 .004 to .08 52* No Trip 2 to 60 1.8 to 30 1 to 10 .15 to 2.0 .015 to 1 .008 to .5 .006 to .1 53* No Trip 80 to 700 40 to 400 15 to 150 2 to 20 .015 to 9 .015 to .55 .012 to .2 59* No Trip .120 Max .100 Max .050 Max .022 Max .017 Max .017 Max .017 Max 61* No Trip .700 to 12 .35 to 7.0 .130 to 3.0 .030 to 1 .015 to .3 .01 to .15 .008 to .1 62* No Trip 10 to 120 6 to 60 2 to 20 .2 to 3.0 .015 to 2 .015 to .8 .01 to .25 63* No Trip 50 to 700 30 to 400 10 to 150 1.5 to 20 .015 to 10 .013 to .85 .013 to .5 64 No Trip .7 to 12 .35 to 7 .13 to 3 .030 to 1 .017 to .3 .01 to .16 .008 to .1 65 No Trip 10 to 120 6 to 60 2 to 20 .2 to 3 .02 to 2 .017 to .76 .01 to. 6 66 No Trip 50 to 700 30 to 400 10 to 150 1.5 to 20 .4 to 10 .014 to 5 .014 to 3 69* No Trip .120 Max .100 Max .050 Max .022 Max .017 Max .017 Max .017 Max 71** No Trip .440 to 10 .300 to 7 .100 to 3.0 .03 to 1 .012 to .3 .004 to .15 .004 to .1 72** No Trip 1.8 to 100 1.7 to 60 1 to 20 .15 to 3 .015 to 2 .008 to .79 .006 to .28 73** No Trip 50 to 600 30 to 400 10 to 150 1.8 to 20 .015 to 10 .015 to .88 .011 to .50 79** No Trip .120 Max .100 Max .050 Max .023 Max .016 Max .015 Max .015 Max *CEG type units are available only with 51, 52, ,53 and 59 delays LEG type units are available only with 61, 62, 63 and 69 delays **135% minimum trip point for delays 71, 72, 73 and 79 INRUSH PULSE TOLERANCE Delay Pulse Tolerance 61, 62, 63, 71, 72, 73 10 times rated current (approx) 61F, 62F, 63F, 71F, 72F, 73F 12 times rated current (approx) 64, 65, 66 25 times rated current (approx) IAG Series - Operating Characteristics 110 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |