| Electronic Components Datasheet Search |
|
LEG Datasheet(PDF) 22 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
LEG Datasheet(HTML) 22 Page - Sensata Technologies, Inc. |
|
22 / 24 page ![]() Internal Configuration Third Decision 3 * Only one auxiliary switch is normally supplied on two pole units. Switch is located in the right-hand pole (viewed from terminal end) unless otherwise specified. -1 -1REC4 -1REC5 -1REG4 -1RS4 -1RLS4 -3 Series Series w/ auxiliary switch * .110 quick connect Series w/ auxiliary switch * .187 quick connect Series w/ auxiliary switch* (gold contacts) .110 quick connect Series w/ alarm switch*, electrical trip, .110 Q.C. terminals Series w/ alarm switch*, electrical trip, mid-trip only, .110 Q.C. terminals Shunt 1 2 3 4 LEG 6 - 1REC4 - 61 - 20.0 - 01 - V 5 7 Example: Black Yellow Red Blue Green Orange White -00 -10 -20 -30 -40 -60 -90 -01 (STD) -11 -21 -31 -41 -61 -91 Seventh Decision 7 Handle Color and Marking Selection Toggle Handle Fifth Decision 5 Rated Current Use three numbers to print required current value between .100 amps minimum and 30.0 amps maximum. For example, use: .100 or 2.00 or 10.0 Fourth Decision 4 Frequency and Delay 50/60Hz short delay 50/60Hz long delay 50/60Hz motor start 50/60Hz 125% instant trip For addition of inertial delay, add an “F” to any delay numeral. (Not available on units rated at 125VAC). * CEG types are only available with DC ratings -61 -62 -63 -69 Notes: A. Bezels of LEGBX are black. B. Consult factory for other marking options. Black Red Grey Orange White -00 -20 -40 -50 -90 -01 -21 -41 -51 -91 -02 -22 -42 -52 -92 -03 -23 -43 -53 -93 -04 -24 -44 -54 -94 -05 -25 -45 -55 -95 -06 -26 -46 -56 -96 I-O Fig.2 Unmarked Marking Detail Seventh Decision 7 Rocker Handle Color, Indicator Color and Marking Selection (See Note) LEGZX Rocker Handle (Single Rocker Color) Rocker Handle Color Indicating Color Marking Color Indicates: On-Off Fig.1 On-Off I-O Fig.3 On-Off I-O Fig.6 I-O Fig.5 On-Off Fig.4 A Vertical Mounting Horizontal Mounting N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Black Black Black White Red Green White Red Green White Red Green White White White On On On -J0 -K0 -L0 -J1 -K1 -L1 -J2 -K2 -L2 -J3 -K3 -L3 -J4 -K4 -L4 -J5 -K5 -L5 -J6 -K6 -L6 B C LEGZX Rocker Handle (Dual Rocker Color) Black Black Black Black Black Black White White White White White White White White Black Black Black On On On Off Off Off -A0 -B0 -C0 -F0 -G0 -H0 -A1 -B1 -C1 -F1 -G1 -H1 -A2 -B2 -C2 -F2 -G2 -H2 -A3 -B3 -C3 -F3 -G3 -H3 -A4 -B4 -C4 -F4 -G4 -H4 -A5 -B5 -C5 -F5 -G5 -H5 -A6 -B6 -C6 -F6 -G6 -H6 Black Black Black Black White Red Green Yellow White Red Green Yellow Off Off Off Off -M0 -N0 -P0 -R0 N/A N/A N/A N/A -M2 -N2 -P2 -R2 -M3 -N3 -P3 -R3 N/A N/A N/A N/A -M6 -N6 -P6 -R6 N/A N/A N/A N/A A LEGBX Rocker Handle (Dual Rocker Color) Sixth Decision 6 Notes: 1. One or more descriptions may be used as required. 2. When this is not used, table one may be substituted and U.S. thread will be supplied. Unit will be rated at 250V (50/60Hz only.) 3. LEGS standard face plate has beveled sides(see pg. 90) * Not available on mid-trip units -A -G -L -S -X* -Z Standard hardware. No designation required. Metric thread mounting inserts and terminals Handle guard, (available in ZX, BX and snap-in versions only) Handle lock Face plate sides flush with breaker Handle guard with no actuation feature (BX rocker only) "Z" Barriers Optional The shaded areas denote VDE approval options. This approval requires the addition of a V at the end of the part number. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be VDE Approved, but other approvals still apply. V = VDE Approved 6 Color Unmarked Marked ON-OFF I-O Handle marking color is white on black, red, blue & green handles and black on white, yellow and orange handles. See alternate 7th decision below for ZX & BZ rocker handles. Standard toggle/mounting, no designation required Toggle w/ snap-in mounting ZX Rocker w/ integral mounting* BX Rocker w/ integral mounting SelectType andTerminal First Decision 1 LEG LMG LEGH LMGH Type Handle and Mounting Options S ZX BX Description One toggle handle per unit One toggle handle per unit mid-trip indication One toggle handle per pole One toggle handle per pole mid-trip indication Note: Add "F" for flat screw terminals * Not available on mid-trip units Note: All types are UL489 listed, CUL certified *Not available in toggle seal handle type. Second Decision 2 Poles andTerminals 1 11 6 66 Push-on Terminals Screw Terminals Single pole Two pole This approval requires the addition of a C at the end of the part number. The unit will not be VDE Approved. C = CCC Approved LEG DECISION TABLES The ordering code for LEG circuit breakers may be determined by following the decision steps in the tables shown here. The coding given permits a self-assigning part number but with certain limitations. Special applications may require a factory-assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table. With these, it is suggested that order entry be by description and/or drawings and a part number will be established. Additionally, it is standard policy to establish a factory- assigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control. When specifying a circuit breaker for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection. For example, the following is the code for a single pole, LEG screw type terminal, series unit with auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, a rating of 20 amperes, a black marked handle and is VDE approved. To determine the ordering number for your particular LEG unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have. Notes: A. When “A” (metric thread mounting) is specified in the sixth decision in combination with screw terminal option in the second decision, metric screw terminals are supplied. B. LEG, LEGH, LEGS, LEGHS, LEGZX and LEGBX circuit breakers are designed to meet 8mm creepage and clearance requirements for installation Category III, Pollution Degree 3, Case A as measured in IEC 664. Intended for use in equipment designed to comply with IEC 601 and 950 and VDE 0804 and 0805. LEG Series - Decision Tables http://airpax.sensata.com 119 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |