13 / 19 page ![]() 2.0 LM95241 Registers (Continued) 2.1 STATUS REGISTER (Read Only Address 02h): D7 D6 D5 D4 D3 D2 D1 D0 Busy Reserved R2TME R1TME RD2M RD1M 000 Bits Name Description 7 Busy When set to "1" the part is converting. 6-4 Reserved Reports "0" when read. 3 Remote 2 TruTherm Mode Enabled (R2TME) When set to "1" indicates that the TruTherm Mode has been activated for Remote diode 2. After being enabled TruTherm Mode will take at most one conversion cycle to be fully active. This bit will be set even if the diode is desconnected. 2 Remote 1 TruTherm Mode Enabled (R1TME) When set to "1" indicates that the TruTherm Mode has been activated for Remote diode 1. After being enabled TruTherm Mode will take at most one conversion cycle to be fully active. This bit will be set even if the diode is disconnected. 1 Remote Diode 2 Missing (RD2M) When set to "1" Remote Diode 2 is missing. (See Section 1.6 for further details.) Temperature Reading is FFE0h which converts to 255.875 ˚C if unsigned format is selected or 8000h which converts to –128.000 ˚C if signed format is selected. Note, connecting a 3904 transistor to Remote 2 inputs with TruTherm mode active may also cause this bit to be set. 0 Remote Diode 1 Missing (RD1M) When set to "1" Remote Diode 1 is missing. (See Section 1.6 for further details.) Temperature Reading is FFE0h which converts to 255.875 ˚C if unsigned format is selected or 8000h which converts to –128.000 ˚C if signed format is selected. Note, connecting a 3904 transistor to Remote 1 inputs with TruTherm mode active may also cause this bit to be set. 2.2 CONFIGURATION REGISTER (Read Address 03h /Write Address 03h): D7 D6 D5 D4 D3 D2 D1 D0 0 RUN/STOP CR1 CR0 0 R2DF R1DF 0 Bits Name Description 7 Reserved Reports "0" when read. 6 RUN/STOP Logic 1 disables the conversion and puts the part in standby mode. Conversion can be activated by writing to one-shot register. 5-4 Conversion Rate (CR1:CR0) 00: continuous mode 76.5 ms, 13.1 Hz (typ), when TruTherm Mode is disabled (Diode Equation) for both remote channels; 77.8 ms, 12.9 Hz (typ), when TruTherm Mode is enabled (Transistor Equation) for one remote channel. 01: converts every 182 ms, 5.5 Hz (typ) 10: converts every 1 second, 1 Hz (typ) 11: converts every 2.7 seconds, 0.37 Hz (typ) 3 Reserved Reports "0" when read. 2 Remote 2 Data Format (R2DF) Logic 0: unsigned Temperature format (0 ˚C to +255.875 ˚C) Logic 1: signed Temperature format (-128 ˚C to +127.875 ˚C) 1 Remote 1 Data Format (R1DF) Logic 0: unsigned Temperature format (0 ˚C to +255.875 ˚C) Logic 1: signed Temperature format (-128 ˚C to +127.875 ˚C) 0 Reserved Reports "0" when read. Power up default is with all bits “0” (zero) www.national.com 13 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |