Back Button PCF8584 Datasheet HTML 7Page - NXP Semiconductors PCF8584 Datasheet HTML 8Page - NXP Semiconductors PCF8584 Datasheet HTML 9Page - NXP Semiconductors PCF8584 Datasheet HTML 10Page - NXP Semiconductors PCF8584 Datasheet HTML 11Page - NXP Semiconductors PCF8584 Datasheet HTML 12Page - NXP Semiconductors PCF8584 Datasheet HTML 13Page - NXP Semiconductors PCF8584 Datasheet HTML 14Page - NXP Semiconductors PCF8584 Datasheet HTML 15Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 40 page
background image
1997 Oct 21
11
Philips Semiconductors
Product specification
I2C-bus controller
PCF8584
6.8.1.5
STA and STO
These bits control the generation of the I2C-bus START condition and transmission of slave address and R/W bit,
generation of repeated START condition, and generation of the STOP condition (see Table 7).
Table 6
Register access control; ESO = 1 (serial interface on) and ES1 = 1; long-distance (4-wire) mode; note 1
Note
1. Trying to read from or write to registers other than S0 and S1 (setting ESO = 0) brings the PCF8584 out of the
long-distance mode.
Table 7
Instruction table for serial bus control
Notes
1. In master receiver mode, the last byte must be terminated with ACK bit HIGH (‘negative acknowledge’).
2. If both STA and STO are set HIGH simultaneously in master mode, a STOP condition followed by a START
condition + address will be generated. This allows ‘chaining’ of transmissions without relinquishing bus control.
3. All other STA and STO mode combinations not mentioned in Table 7 are NOPs.
6.8.1.6
ACK
This bit must be set normally to a logic 1. This causes the I2C-bus controller to send an acknowledge automatically after
each byte (this occurs during the 9th clock pulse). The bit must be reset (to logic 0) when the I2C-bus controller is
operating in master/receiver mode and requires no further data to be sent from the slave transmitter. This causes a
negative acknowledge on the I2C-bus, which halts further transmission from the slave device.
6.8.2
REGISTER S1 STATUS SECTION
The read-only section of S1 enables access to I2C-bus status information; see Table 4.
INTERNAL REGISTER ADDRESSING: LONG-DISTANCE (4-WIRE) MODE
A0
ES1
ES2
IACK
FUNCTION
1
1
X
1
W S1: control
1
1
X
X
R S1; status
0
1
X
X
R/W S0; (data)
STA
STO
PRESENT
MODE
FUNCTION
OPERATION
1
0
SLV/REC
START
transmit START + address, remain
MST/TRM if R/W=0;
go to MST/REC if R/W=1
1
0
MST/TRM
REPEAT
START
same as for SLV/REC
0
1
MST/REC;
MST/TRM
STOP READ;
STOP WRITE
transmit STOP go to SLV/REC mode; note 1
1
1
MST
DATA
CHAINING
send STOP, START and address after last
master frame without STOP sent; note 2
0
0
ANY
NOP
no operation; note 3



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com