12 / 40 page ![]() 1997 Oct 21 12 Philips Semiconductors Product specification I2C-bus controller PCF8584 6.8.2.1 PIN bit ‘Pending Interrupt Not’ (MSB of register S1) is a status flag which is used to synchronize serial communication and is set to logic 0 whenever the PCF8584 requires servicing. The PIN bit is normally read in polled applications to determine when an I2C-bus byte transmission/reception is completed. The PIN bit may also be written, see Section 6.8.1. Each time a serial data transmission is initiated (by setting the STA bit in the same register), the PIN bit will be set to logic 1 automatically (inactive). When acting as transmitter, PIN is also set to logic 1 (inactive) each time S0 is written. In receiver mode, the PIN bit is automatically set to logic 1 (inactive) each time the data register S0 is read. After transmission or reception of one byte on the I2C-bus (9 clock pulses, including acknowledge), the PIN bit will be automatically reset to logic 0 (active) indicating a complete byte transmission/reception. When the PIN bit is subsequently set to logic 1 (inactive), all status bits will be reset to logic 0. PIN is also set to zero on a BER (bus error) condition. In polled applications, the PIN bit is tested to determine when a serial transmission/reception has been completed. When the ENI bit (bit 4 of write-only section of register S1) is also set to logic 1 the hardware interrupt is enabled. In this case, the PIN flag also triggers an external interrupt (active LOW) via the INT output each time PIN is reset to logic 0 (active). When acting as slave transmitter or slave receiver, while PIN = 0, the PCF8584 will suspend I2C-bus transmission by holding the SCL line LOW until the PIN bit is set to logic 1 (inactive). This prevents further data from being transmitted or received until the current data byte in S0 has been read (when acting as slave receiver) or the next data byte is written to S0 (when acting as slave transmitter). PIN bit summary: • The PIN bit can be used in polled applications to test when a serial transmission has been completed. When the ENI bit is also set, the PIN flag sets the external interrupt via the INT output. • Setting the STA bit (start bit) will set PIN = 1 (inactive). • In transmitter mode, after successful transmission of one byte on the I2C-bus the PIN bit will be automatically reset to logic 0 (active) indicating a complete byte transmission. • In transmitter mode, PIN is set to logic 1 (inactive) each time register S0 is written. • In receiver mode, PIN is set to logic 0 (active) on completion of each received byte. Subsequently, the SCL line will be held LOW until PIN is set to logic 1. • In receiver mode, when register S0 is read, PIN is set to logic 1 (inactive). • In slave receiver mode, an I2C-bus STOP condition will set PIN = 0 (active). • PIN = 0 if a bus error (BER) occurs. 6.8.2.2 STS When in slave receiver mode, this flag is asserted when an externally generated STOP condition is detected (used only in slave receiver mode). 6.8.2.3 BER Bus error; a misplaced START or STOP condition has been detected. Resets BB (to logic 1; inactive), sets PIN = 0 (active). 6.8.2.4 LRB/AD0 ‘Last Received Bit’ or ‘Address 0 (General Call) bit’. This status bit serves a dual function, and is valid only while PIN = 0: 1. LRB holds the value of the last received bit over the I2C-bus while AAS = 0 (not addressed as slave). Normally this will be the value of the slave acknowledgement; thus checking for slave acknowledgement is done via testing of the LRB. 2. AD0; when AAS = 1 (‘Addressed As Slave’ condition), the I2C-bus controller has been addressed as a slave. Under this condition, this bit becomes the ‘AD0’ bit and will be set to logic 1 if the slave address received was the ‘general call’ (00H) address, or logic 0 if it was the I2C-bus controller’s own slave address. 6.8.2.5 AAS ‘Addressed As Slave’ bit. Valid only when PIN = 0. When acting as slave receiver, this flag is set when an incoming address over the I2C-bus matches the value in own address register S0' (shifted by one bit, see Section 6.4), or if the I2C-bus ‘General Call’ address (00H) has been received (‘General Call’ is indicated when AD0 status bit is also set to logic 1, see Section 6.8.2.4). 6.8.2.6 LAB ‘Lost Arbitration’ Bit. This bit is set when, in multi-master operation, arbitration is lost to another master on the I2C-bus. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |