Back Button EPR-9 Datasheet HTML 24Page - Power Integrations, Inc. EPR-9 Datasheet HTML 25Page - Power Integrations, Inc. EPR-9 Datasheet HTML 26Page - Power Integrations, Inc. EPR-9 Datasheet HTML 27Page - Power Integrations, Inc. EPR-9 Datasheet HTML 28Page - Power Integrations, Inc. EPR-9 Datasheet HTML 29Page - Power Integrations, Inc. EPR-9 Datasheet HTML 30Page - Power Integrations, Inc. EPR-9 Datasheet HTML 31Page - Power Integrations, Inc. EPR-9 Datasheet HTML 32Page - Power Integrations, Inc.  
Zoom Inzoom in Zoom Outzoom out
 28 / 32 page
background image
5 W Universal Input Dual Output Isolated TNY266
03-April-2001
Transformer Construction
Parameters
Core/Bobbin
EE16
Core and Bobbin Type
Core Manuf.
Generic
Core Manufacturing
Bobbin Manuf.
Generic
Bobbin Manufacturing
LPmin
uHenries
954
Minimum Primary Inductance
NP
76
Primary Winding Number of Turns
AWG
AWG
30
Primary Wire Gauge (Rounded to next smaller
standard AWG value)
CMA
Cmils/A
722
Primary Winding Current Capacity (200 < CMA <
500). Warning! Primary circular mils per amp (CMA)
is too high. Decrease transformer size, decrease L,
increase NS, decrease VACmin, increase VOR,
increase KrpKdp.
VOR
Volts
60.00
Reflected Output Voltage
BW
mm
8.50
Bobbin Physical Winding Width
M
mm
0.0
Safety Margin Width
L
3.0
Number of Primary Layers
AE
cm^2
0.19
Core Effective Cross Section Area
ALG
nH/T^2
164
Gapped Core Effective Inductance
BM
Gauss
2553
Maximum Operating Flux Density
BAC
Gauss
924
AC Flux Density
LG
mm
0.13
Gap Length (Lg > 0.051 for TOP22X, Lg > 0.1 for
TOP23X)
LL
uH
19.1
Estimated Transformer Primary Leakage Inductance
LSEC
nH
20
Estimated Secondary Trace Inductance
Secondary
Parameters
NSx
7.00
31.82 Secondary Number of Turns
Rounded Down
NSx
31 Rounded to Integer Secondary Number of Turns
Rounded Down
Vox
Volts
23.36 Auxiliary Output Voltage for Rounded to Integer NSx
Rounded Up
NSx
32 Rounded to Next Integer Secondary Number of Turns
Rounded Up
Vox
Volts
24.14 Auxiliary Output Voltage for Rounded to Next Integer
NSx
AWGSx Range AWG
24 - 28
31 - 35
Secondary Wire Gauge Range (CMA range 500 - 200).
Wire gauge (AWG) is less than 26 AWG. Consider
parallel winding (see AN-18, AN-22).
Page 28 of 32
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com