Electronic Components Datasheet Search
  English  ▼

X  

EPR-9 Datasheet(PDF) 14 Page - Power Integrations, Inc.

Part # EPR-9
Description  Engineering Prototype Report 5 W, Universal Input, Dual Output, Isolated, TNY266 (EP9)
PDF  32 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  POWERINT [Power Integrations, Inc.]
Direct Link  http://www.powerint.com
Logo POWERINT - Power Integrations, Inc.

EPR-9 Datasheet(HTML) 14 Page - Power Integrations, Inc.

Back Button EPR-9 Datasheet HTML 10Page - Power Integrations, Inc. EPR-9 Datasheet HTML 11Page - Power Integrations, Inc. EPR-9 Datasheet HTML 12Page - Power Integrations, Inc. EPR-9 Datasheet HTML 13Page - Power Integrations, Inc. EPR-9 Datasheet HTML 14Page - Power Integrations, Inc. EPR-9 Datasheet HTML 15Page - Power Integrations, Inc. EPR-9 Datasheet HTML 16Page - Power Integrations, Inc. EPR-9 Datasheet HTML 17Page - Power Integrations, Inc. EPR-9 Datasheet HTML 18Page - Power Integrations, Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 32 page
background image
5 W Universal Input Dual Output Isolated TNY266
03-April-2001
Transformer Construction
Parameters
Core/Bobbin
EE16
Core and Bobbin Type
Core Manuf.
Generic
Core Manufacturing
Bobbin Manuf.
Generic
Bobbin Manufacturing
LPmin
uHenries
978
Minimum Primary Inductance
NP
76
Primary Winding Number of Turns
AWG
AWG
30
Primary Wire Gauge (Rounded to next smaller
standard AWG value)
CMA
Cmils/A
696
Primary Winding Current Capacity (200 < CMA <
500). Warning! Primary circular mils per amp (CMA)
is too high. Decrease transformer size, decrease L,
increase NS, decrease VACmin, increase VOR,
increase KrpKdp.
VOR
Volts
60.00
Reflected Output Voltage
BW
mm
8.50
Bobbin Physical Winding Width
M
mm
0.0
Safety Margin Width
L
3.0
Number of Primary Layers
AE
cm^2
0.19
Core Effective Cross Section Area
ALG
nH/T^2
168
Gapped Core Effective Inductance
BM
Gauss
2611
Maximum Operating Flux Density
BAC
Gauss
900
AC Flux Density
LG
mm
0.12
Gap Length (Lg > 0.051 for TOP22X, Lg > 0.1 for
TOP23X)
LL
uH
19.6
Estimated Transformer Primary Leakage Inductance
LSEC
nH
20
Estimated Secondary Trace Inductance
Secondary
Parameters
NSx
7.00
16.16 Secondary Number of Turns
Rounded Down
NSx
16 Rounded to Integer Secondary Number of Turns
Rounded Down
Vox
Volts
11.87 Auxiliary Output Voltage for Rounded to Integer NSx
Rounded Up
NSx
17 Rounded to Next Integer Secondary Number of Turns
Rounded Up
Vox
Volts
12.66 Auxiliary Output Voltage for Rounded to Next Integer
NSx
AWGSx Range AWG
24 - 28
28 - 32
Secondary Wire Gauge Range (CMA range 500 - 200).
Wire gauge (AWG) is less than 26 AWG. Consider
parallel winding (see AN-18, AN-22).
Page 14 of 32
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com