| Electronic Components Datasheet Search |
|
AMC7891 Datasheet(PDF) 25 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC7891 Datasheet(HTML) 25 Page - Texas Instruments |
|
25 / 43 page ![]() ADC AIN0 To Shift Register . . . adc_ready Input Range Selection AIN7 adc_trig (Internal Trigger) AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 DAV GPIOVDD 10 kW adc0_tmpry adc0_data adc7_tmpry adc7_data AMC7891 www.ti.com SBAS518A – AUGUST 2011 – REVISED DECEMBER 2011 When any of the following events occur, the current conversion cycle stops immediately: • A new trigger is issued. • The conversion mode changes. • Either ADC channe register is rewritten. When a new trigger activates, the ADC starts a new conversion cycle. The trigger should not be issued at the same time the conversion mode is changed. If a ‘1’ is simultaneously written to the adc_trig bit when changing the adc_mode bit from ‘0’ to '1', the current conversion stops and immediately returns to the wait for ADC trigger state. To avoid noise caused by the bus clock, it is recommended that no bus clock activity occurs for at least the conversion process time immediately after the ADC conversion starts. DOUBLE-BUFFERED ADC DATA REGISTER The host can access all eight, double-buffered ADCn_data registers, as shown in Figure 28. The conversion result from the analog input with channel address n, (where n = 0 to 7) is stored in adcn_data[9:0] in straight binary format. When the conversion of an individual channel is completed, the data is immediately transferred into the corresponding adcn_tmpry temporary register, the first stage of the data buffer. When the conversion of the last channel completes, all data in the adcn_tmpry registers is simultaneously transferred to the corresponding adcn_data[9:0] value, the second stage of the data buffer. In the case when a data transfer is in progress between any ADCn_data register and the AMC7891 shift register, all ADCn_data registers are not updated until the data transfer is complete. Figure 28. ADC Structure PROGRAMMABLE CONVERSION RATE The maximum ADC conversion rate is 500 kSPS for a single channel in auto mode, as shown in Table 3. The conversion rate is programmable through adc_rate[1:0] (AMC_config register, [9:8] bits). When more than one channel is selected, the conversion rate is divided by the number of channels selected in register ADC_enable. In auto mode, the adc_rate[1:0] value determines the actual conversion rate. In direct mode, adc_rate[1:0] limits the maximum possible conversion rate. The actual conversion rate in direct mode is determined by the rate of the conversion trigger. Note that when a trigger is issued, there may be a delay of up to 4 μs to internally synchronize and initiate the start of the sequential channel conversion process. In both direct- and auto- modes, when adc_rate[1:0] is set to a value other than the maximum rate ('00'), nap mode is activated between conversions. By activating nap mode, the AVDD supply current is reduced. Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback 25 Product Folder Link(s): AMC7891 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |