20 / 37 page ![]() RXD (receiver) TXD (driver) CAN Bus Signal Normal CAN communication TXD fault stuck dominant Example: PCB failure or bad software Driver disabled freeing bus for other nodes Bus would be stuck dominant, blocking communication for the whole network but TXD DTO prevents this and frees the bus for communication after the tTXD_DTO time. tTXD_DTO tTXD_DTO Fault is repaired and transmission capability is restored Communication from other bus nodes Communication from repaired nodes Communication from other bus nodes Communication from repaired nodes Communication from local node Figure 8-3. Example Timing Diagram for TXD DTO Note The minimum dominant TXD time (tTXD_DTO) allowed by the TXD DTO circuit limits the minimum possible transmitted data rate of the device. The CAN protocol allows a maximum of eleven successive dominant bits (on TXD) for the worst case, where five successive dominant bits are followed immediately by an error frame. This, along with the tTXD_DTO minimum, limits the minimum data rate. Calculate the minimum transmitted data rate with Equation 1. Minimum Data Rate = 11 / tTXD_DTO (1) 8.3.3.2 Thermal Shutdown (TSD) If the junction temperature of the device exceeds the thermal shutdown threshold (TTSD), the device turns off the CAN driver circuits, blocking the TXD-to-bus transmission path. The CAN bus terminals are biased to the recessive level during a thermal shutdown, and the receiver-to-RXD path remains operational. The shutdown condition is cleared when the junction temperature drops at least the thermal shutdown hysteresis temperature (TTSD_HYST) below the thermal shutdown temperature (TTSD) of the device. 8.3.3.3 Undervoltage Lockout and Default State The supply pins have undervoltage detection that places the device in protected or default mode which protects the bus during an undervoltage event on the VCC1 or VCC2 supply pins. If the bus-side power supply, VCC2, is less than about 4 V, the power shutdown circuits in the ISO1044B device disable the transceiver to prevent false transmissions because of an unstable supply. If the VCC1 supply is still active when this occurs, the receiver output (RXD) goes to a default HIGH (recessive) value. Table 8-1 summarizes the undervoltage lockout and fail- safe behavior. Table 8-1. Undervoltage Lockout and Default State VCC1 VCC2 DEVICE STATE BUS OUTPUT RXD > UVVCC1 > UVVCC2 Functional Per Device State and TXD Mirrors Bus <UVVCC1 > UVVCC2 Protected Recessive Undetermined >UVVCC1 < UVVCC2 Protected High Impedance Recessive (Default High) ISO1044 SLLSFB0A – MARCH 2020 – REVISED JULY 2020 www.ti.com 20 Submit Document Feedback Copyright © 2020 Texas Instruments Incorporated Product Folder Links: ISO1044 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |