IP113F
Preliminary Data Sheet
1.
PIN Description (continued)
Pin no.
Label
Type
Description
LED pins
31
LED_TP_LINK
O
TP port link LED
On: link ok,
Off: link fail,
Flash: link ok & activity
(Flash: on for 20ms and off for 80ms)
33
LED_TP_SPD
O
TP port speed LED
On: 100M,
Off: 10M
32
LED_TP_FDX
O
TP port full duplex LED
On: full,
Off: half,
Flash: half & collision happens
(Flash: on for 20ms and off for 80ms)
36
LED_FX_LINK
O
Fiber port link LED
On: link ok,
Off: link fail,
Flash: link ok & activity
(Flash: on for 20ms and off for 80ms)
37
LED_FX_FDX
O
Fiber port full duplex LED
On: full,
Off: half,
Flash: half & collision happens
(Flash: on for 20ms and off for 80ms)
38
LED_FX_SD
O
Fiber port signal detect
On: fiber signal detected,
Off: fiber unplugged
30
LED_FX_FEF_DET
O
Far end fault pattern received
For End Fault Patterns Receive
LED On: 80ms, LED Off: 20ms
For End Fault Pattern not Receive
LED always Off
29
LED_RMT_TP_LINK
O
LED for link status of TP port of remote IP113F
When AUTO_TEST is logic low,
On: link ok,
Off: link fail
When AUTO_TEST is pulled high, it is always flash in a
period of 100ms (On: 80ms, Off: 20ms)
25
LED_RMP_TP_SPD
O
LED for speed of TP port of remote IP113F
When AUTO_TEST is logic low,
On: 100M,
Off: 10M
When AUTO_TEST is pulled high,
On: loop back test complete,
Off: during loop back test
24
LED_RMT_TP_FDX
O
LED for full duplex of TP port of remote IP113F
When AUTO_TEST is logic low,
On: full,
Off: half
When AUTO_TEST is pulled high,
On: loop back test ok,
Off: loop back test fail
Note: The output of LED pin is logic low when the LED is on.
Confidential.
6/46
Aug. 20, 2003
Copyright © 2003, IC Plus Corp.
IP113F-DS-R02