| Electronic Components Datasheet Search |
|
DIO2488CSC6 Datasheet(PDF) 16 Page - DIOO MICROCIRCUITS CO., LTD |
|
|
|||||||||||||||||||||||||||||
DIO2488CSC6 Datasheet(HTML) 16 Page - DIOO MICROCIRCUITS CO., LTD |
|
16 / 19 page ![]() DIO2488 Version 1.2, Dec 2025 www.dioo.com © 2025 Dioo Microcircuits Co., Ltd. Jiangsu 13 11.Layout Guidelines Use a kelvin or 4-wire connection to connect the input pins to the sensing resistor. This connection technique ensures that only the current-sensing resistor impedance is detected between the input pins. If the routing of the current-sensing resistor is poor, it commonly results in additional resistance between the input pins. Given the very low ohmic value of the current resistor, any additional high-current carrying impedance can cause significant measurement errors. The power-supply bypass capacitor should be located close to the supply and ground pins as much as possible. DIOO recommends that the value of the bypass capacitor should be 0.1 μF. To compensate for noisy or high-impedance power supplies, the additional decoupling capacitance can be added. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |