| Electronic Components Datasheet Search |
|
AD5683R Datasheet(PDF) 1 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5683R Datasheet(HTML) 1 Page - Analog Devices |
|
1 / 12 page ![]() Circuit Note CN-0411 Circuits from the Lab® reference designs are engineered and tested for quick and easysystemintegrationto helpsolve today’s analog, mixed-signal, and RF design challenges. For more informationand/orsupport, visit www.analog.com/CN0411. Devices Connected/Referenced AD7124-8 8-Channel, Low Noise, Low Power, 24-Bit, Sigma-Delta ADC with PGA and Reference AD8628 Zero-Drift, Single-Supply, RRIO Op Amp ADG836 0.5 Ω CMOS, 1.65 V to 3.6 V Dual SPDT/2:1 MUX AD8220 JFET Input Instrumentation Amplifier with Rail- to-Rail Output ADG884 0.5 Ω CMOS Dual 2:1 MUX/SPDT ADG1608 4.5 Ω RON, 8-Channel ±5 V, +12 V, +5 V, and +3.3 V Multiplexer AD5683R Tiny 16-Bit SPI nanoDAC+, with ±2 (16-Bit) LSB INL and 2 ppm/°C External Reference TDS Measurement System for Water Quality Monitoring Rev. 0 CircuitsfromtheLabreferencedesignsfromAnalogDeviceshavebeendesignedandbuiltbyAnalog Devices engineers. Standard engineering practices have been employed in the design and constructionofeachcircuit,andtheirfunctionandperformancehavebeentestedandverifiedinalab environment at room temperature. However, you are solely responsible for testing the circuit and determiningitssuitabilityandapplicabilityforyouruseandapplication.Accordingly,innoeventshall AnalogDevicesbeliablefordirect,indirect,special,incidental,consequentialorpunitivedamagesdue toanycausewhatsoeverconnectedtotheuseofanyCircuitsfromtheLabcircuits. (Continuedonlastpage) One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 ©2018 Analog Devices, Inc. All rights reserved. EVALUATION AND DESIGN SUPPORT Circuit Evaluation Boards CN-0411 Circuit Evaluation Board (EVAL-CN0411-ARDZ) ADICUP360 Development Board (EVAL-ADICUP360) Design and Integration Files Schematics, Layout Files, Bill of Materials, Software CIRCUIT FUNCTION AND BENEFITS The total dissolved solids (TDS) present in a water system is composed of inorganic salts and small amounts of organic matter that are dissolved in water, and is an important measure of water quality. TDS can be derived from the electrical conductivity (or conductivity) of the solution by a factor dependent on the properties, temperature and, number of ions present. By measuring the conductivity of the solution, determining the TDS of the system is faster, economical, and less complicated in contrast to the more accurate gravimetric method. The latter method involves evaporating the water and weighing the residue, which is applicable in laboratory settings but impractical in the field. The circuit shown in Figure 1 is a TDS measurement system based on the conductivity of the solution. This design uses a combination of components that allow for single-supply operation, which minimize circuit complexity, making this suitable for low-power and portable instrument applications. The simplest method of measuring the conductivity of the solution uses a 2-wire conductivity cell. Conductivity measurements require temperature compensation for measurements taken at temperatures other than 25˚C (or other reference temperature). This system can reference the conductivity measurement to room temperature using either a 100 Ω or 1000 Ω, 2-wire resistance temperature device (RTD) and can accommodate 2-wire conductivity cells of various cell constants and operating parameters. The capacitance and polarization effects of the electrodes in the conductivity cell require that the excitation signal be a bipolar square wave with a sufficiently high frequency to reduce polarization effects but also with sufficiently long periods to reduce capacitance effects. To avoid damaging the conductivity electrodes, the signal must have a very low to zero dc offset and magnitude. The circuit can measure the range of conductivity values from 1 µS to 0.1 S. A multiplexer switches between seven precision resistors of different values to set the gain when measuring the conductivity probe signal. The system can automatically determine the gain setting of the conductivity measurement through an auto-ranging procedure implemented in software. The system can also be calibrated in the high conductivity range to increase its accuracy |
Similar Part No. - AD5683R |
|
Similar Description - AD5683R |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |