Electronic Components Datasheet Search
  English  ▼

X  

AD5683R Datasheet(PDF) 1 Page - Analog Devices

Part # AD5683R
Description  TDS Measurement System for Water Quality Monitoring
PDF  12 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AD [Analog Devices]
Direct Link  http://www.analog.com
Logo AD - Analog Devices

AD5683R Datasheet(HTML) 1 Page - Analog Devices

  AD5683R Datasheet HTML 1Page - Analog Devices AD5683R Datasheet HTML 2Page - Analog Devices AD5683R Datasheet HTML 3Page - Analog Devices AD5683R Datasheet HTML 4Page - Analog Devices AD5683R Datasheet HTML 5Page - Analog Devices AD5683R Datasheet HTML 6Page - Analog Devices AD5683R Datasheet HTML 7Page - Analog Devices AD5683R Datasheet HTML 8Page - Analog Devices AD5683R Datasheet HTML 9Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 1 / 12 page
background image
Circuit Note
CN-0411
Circuits from the Lab® reference designs are engineered and
tested for quick and easysystemintegrationto helpsolve today’s
analog, mixed-signal, and RF design challenges. For more
informationand/orsupport, visit www.analog.com/CN0411.
Devices Connected/Referenced
AD7124-8
8-Channel, Low Noise, Low Power, 24-Bit,
Sigma-Delta ADC with PGA and Reference
AD8628
Zero-Drift, Single-Supply, RRIO Op Amp
ADG836
0.5
Ω CMOS, 1.65 V to 3.6 V Dual SPDT/2:1
MUX
AD8220
JFET Input Instrumentation Amplifier with Rail-
to-Rail Output
ADG884
0.5 Ω CMOS Dual 2:1 MUX/SPDT
ADG1608
4.5 Ω RON, 8-Channel ±5 V, +12 V, +5 V, and
+3.3 V Multiplexer
AD5683R
Tiny 16-Bit SPI nanoDAC+, with ±2 (16-Bit) LSB
INL and 2 ppm/°C External Reference
TDS Measurement System for Water Quality Monitoring
Rev. 0
CircuitsfromtheLabreferencedesignsfromAnalogDeviceshavebeendesignedandbuiltbyAnalog
Devices engineers. Standard engineering practices have been employed in the design and
constructionofeachcircuit,andtheirfunctionandperformancehavebeentestedandverifiedinalab
environment at room temperature. However, you are solely responsible for testing the circuit and
determiningitssuitabilityandapplicabilityforyouruseandapplication.Accordingly,innoeventshall
AnalogDevicesbeliablefordirect,indirect,special,incidental,consequentialorpunitivedamagesdue
toanycausewhatsoeverconnectedtotheuseofanyCircuitsfromtheLabcircuits. (Continuedonlastpage)
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2018 Analog Devices, Inc. All rights reserved.
EVALUATION AND DESIGN SUPPORT
Circuit Evaluation Boards
CN-0411 Circuit Evaluation Board (EVAL-CN0411-ARDZ)
ADICUP360 Development Board (EVAL-ADICUP360)
Design and Integration Files
Schematics, Layout Files, Bill of Materials, Software
CIRCUIT FUNCTION AND BENEFITS
The total dissolved solids (TDS) present in a water system is
composed of inorganic salts and small amounts of organic
matter that are dissolved in water, and is an important measure
of water quality. TDS can be derived from the electrical
conductivity (or conductivity) of the solution by a factor
dependent on the properties, temperature and, number of ions
present. By measuring the conductivity of the solution,
determining the TDS of the system is faster, economical, and
less complicated in contrast to the more accurate gravimetric
method. The latter method involves evaporating the water and
weighing the residue, which is applicable in laboratory settings
but impractical in the field.
The circuit shown in Figure 1 is a TDS measurement system
based on the conductivity of the solution. This design uses a
combination of components that allow for single-supply
operation, which minimize circuit complexity, making this
suitable for low-power and portable instrument applications.
The simplest method of measuring the conductivity of the solution
uses a 2-wire conductivity cell. Conductivity measurements
require temperature compensation for measurements taken at
temperatures other than 25˚C (or other reference temperature).
This system can reference the conductivity measurement to
room temperature using either a 100 Ω or 1000 Ω, 2-wire
resistance temperature device (RTD) and can accommodate
2-wire conductivity cells of various cell constants and operating
parameters.
The capacitance and polarization effects of the electrodes in the
conductivity cell require that the excitation signal be a bipolar
square wave with a sufficiently high frequency to reduce
polarization effects but also with sufficiently long periods to
reduce capacitance effects. To avoid damaging the conductivity
electrodes, the signal must have a very low to zero dc offset and
magnitude.
The circuit can measure the range of conductivity values from
1 µS to 0.1 S. A multiplexer switches between seven precision
resistors of different values to set the gain when measuring the
conductivity probe signal. The system can automatically
determine the gain setting of the conductivity measurement
through an auto-ranging procedure implemented in software.
The system can also be calibrated in the high conductivity range
to increase its accuracy


Similar Part No. - AD5683R

ManufacturerPart #DatasheetDescription
logo
Analog Devices
AD5683R AD-AD5683R Datasheet
882Kb / 28P
Tiny 16-/14-/12-Bit SPI nanoDAC
12/2016-Rev. C to Rev. D
AD5683RACPZ-1RL7 AD-AD5683RACPZ-1RL7 Datasheet
882Kb / 28P
Tiny 16-/14-/12-Bit SPI nanoDAC
12/2016-Rev. C to Rev. D
AD5683RACPZ-2RL7 AD-AD5683RACPZ-2RL7 Datasheet
882Kb / 28P
Tiny 16-/14-/12-Bit SPI nanoDAC
12/2016-Rev. C to Rev. D
AD5683RACPZ-RL7 AD-AD5683RACPZ-RL7 Datasheet
882Kb / 28P
Tiny 16-/14-/12-Bit SPI nanoDAC
12/2016-Rev. C to Rev. D
AD5683RARMZ AD-AD5683RARMZ Datasheet
882Kb / 28P
Tiny 16-/14-/12-Bit SPI nanoDAC
12/2016-Rev. C to Rev. D
More results

Similar Description - AD5683R

ManufacturerPart #DatasheetDescription
logo
JDS Uniphase Corporatio...
RPM3000 JDSU-RPM3000 Datasheet
236Kb / 2P
Monitoring Module for PathTrak Return Monitoring System
logo
Linear Technology
LTC2470 LINER-LTC2470 Datasheet
313Kb / 20P
System Monitoring
logo
Freescale Semiconductor...
AN1950 FREESCALE-AN1950 Datasheet
307Kb / 24P
Water Level Monitoring
logo
Maxim Integrated Produc...
78M6610LMU MAXIM-78M6610LMU Datasheet
1Mb / 63P
Energy Measurement Processor for Load Monitoring Units
Rev 0; 1/13
MAX78615LMU MAXIM-MAX78615LMU Datasheet
680Kb / 62P
Isolated Energy Measurement Processor for Load Monitoring Units
Rev 0; 12/12
logo
Pentair plc. All rights...
2H-L PENTAIR-2H-L Datasheet
352Kb / 2P
PREMIUM QUALITY WATER FOR BOTTLELESS COOLER AND DRINKING WATER APPLICATIONS
4CB5-K PENTAIR-4CB5-K Datasheet
263Kb / 2P
DELIVERS QUALITY WATER FOR FOODSERVICE, VENDING AND OCS APPLICATIONS
QL2-OCS PENTAIR-QL2-OCS Datasheet
261Kb / 2P
DELIVERS PREMIUM QUALITY WATER FOR OFFICE COFFEE APPLICATIONS
logo
Maxim Integrated Produc...
MAX78630 MAXIM-MAX78630 Datasheet
900Kb / 77P
Energy Measurement Processor for Polyphase Monitoring Systems
Rev 3; 8/14
78M6610LMU MAXIM-78M6610LMU_V01 Datasheet
829Kb / 67P
Energy Measurement Processor for Load Monitoring Units
2015
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com