| Electronic Components Datasheet Search |
|
7220 Datasheet(PDF) 197 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
7220 Datasheet(HTML) 197 Page - Renesas Technology Corp |
|
197 / 303 page ![]() APPLICATION 5.4 Example of I2C-BUS interface control (M37221Mx-XXXSP/FP) 7220 Group User’s Manual 5-24 (2) Read processing routine Fig. 5.4.5 Flowchart of read processing routine S Slave address (W) “A016” A C K Sub-address A C K Data A C K P R S Slave address (R) “A116” Read start S1 (address 00D9 16) ←“001000002” (A) ←Slave address (R) “A1 16” (A) ←Slave address (W) “A0 16” Transmit the START condition, slave address (W) , and sub-address. Immediately before the last receive byte? Input start (Set dummy data to generate clock.) End of reception of the last receive byte Preparation for judging of timeout. Store recive data to internal RAM Data output Timeout ? (See note 2) End PIN (bit 4 at address 00D9 16) ≠“1”? Data output Yes No Yes No Waiting receive end Yes (end) No (not end) Yes No Set to receive mode Set ACK return mode. After data is received, no acknowledge bits are generated, but the STOP condition is sent by the master, completing this read operation. Set to non-ACK return mode. Initialization S2 (address 00DB 16) S1D (address 00DA 16) S1 (address 00D9 16) IICE (bit6 at address 00FE 16) ←“110001012” ←“010010002” ←“0” ←“000100002” Disable multi-master I 2C-BUS interface. Setting for outputting the START condition in data output processing routine. TRX (bit 6 at address 00D9 16) ACK BIT (bit 6 at address 00DB 16) ←“0” ←“0” ACK BIT (bit 6 at address 00DB 16) ←“1” S0 (address 00D7 16) ←“FF16” I S1 (address 00F8 16) S1 (address 00F8 16) I ←“1” ←“110000002” ←“110100002” ←“0” Transmit the STOP condition. Note 1: Be sure to set between S1 and S1 within 10 machine cycles. Transmit the RESTART condtion and slave address (R). A C K Note 2: The timeout count is performed by software with interrupts, such as timers. Accordingly, if receive 2 2C-BUS access is stopped by timeout, the obtained data is incorrect data. A: S0: S1: S2: S1D: IICE: BB: TRX: ACK BIT: PIN: RS: Accumulator I2C data shift register I2C status register I2C clock control register I2C control register Multi-master I 2C interface interrupt enable bit Bus busy flag Communication mode specification bit ACK bit I2C-BUS interface interrupt request bit Restart condition Within 10 machine cycles operation does not complete within a certain time, I C-BUS access is stopped by outputting STOP operation is not completed due to various influences, the loop continues. Therefore, if receive condition. If I |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |