| Electronic Components Datasheet Search |
|
INA220 Datasheet(PDF) 20 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
INA220 Datasheet(HTML) 20 Page - Texas Instruments |
|
20 / 35 page ![]() Max_Current=Current_LSB 32767 ´ Max_Current=0.06226 (15) Max_ShuntVoltage=Max_Current_Before_Overflow R ´ SHUNT Max_ShuntVoltage=0.3113 (16) MaximumPower=Max_Current_Before_Overflow V ´ BUS_MAX MaximumPower=1.992 (17) Corrected_Full_Scale_Cal=trunc Cal MeasShuntCurrent INA220_Current ´ Corrected_Full_Scale_Cal=3462 (18) INA220 SBOS459B – JUNE 2009 – REVISED JUNE 2009 ............................................................................................................................................................. www.ti.com 7. Compute the maximum current and shunt voltage values (before overflow), as shown by Equation 15 and Equation 16. Note that both Equation 15 and Equation 16 involve an If - then condition. If Max_Current ≥ Max Possible_I then Max_Current_Before_Overflow = MaxPossible_I Else Max_Current_Before_Overflow = Max_Current End If (Note that Max_Current is less than MaxPossible_I in this example.) Max_Current_Before_Overflow = 0.06226 (Note: This result is displayed by software as seen in Figure 21.) If Max_ShuntVoltage ≥ VSHUNT_MAX Max_ShuntVoltage_Before_Overflow = VSHUNT_MAX Else Max_ShuntVoltage_Before_Overflow= Max_ShuntVoltage End If (Note that Max_ShuntVoltage is less than VSHUNT_MAX in this example.) Max_ShuntVoltage_Before_Overflow = 0.3113 (Note: This result is displayed by software as seen in Figure 21.) 8. Compute the maximum power with equation 8. 9. (Optional second calibration step.) Compute the corrected full-scale calibration value based on measured current. INA220_Current = 0.06226 MeaShuntCurrent = 0.05 Figure 21 illustrates how to perform the same procedure discussed in this example using the automated INA220EVM software. Note that the same numbers used in the nine-step example are used in the software example in Figure 21. Also note that Figure 21 illustrates which results correspond to which step (for example, the information entered in Step 1 is enclosed in a box in Figure 21 and labeled). 20 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): INA220 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |