31 / 56 page ![]() AD7193 Rev. A | Page 31 of 56 available on each channel. When several channels are enabled, the contents of the status register should be attached to the 24-bit word allowing the user to identify the channel that corresponds to each conversion. The four LSBs of the status register indicate the channel to which the conversion corresponds. and show the channel options for differential mode and pseudo differential mode with the corresponding channel ID values in the status register. To attach the status register value to the conversion, Bit DAT_STA in the mode register should be set to 1. Table 22 Table 23 When several channels are enabled, the ADC allows the complete filter settling time to generate a valid conversion each time that the channel is changed. The AD7193 automatically takes care of this through the following sequence: 1. When a channel is selected, the modulator and filter are reset. 2. The AD7193 allows the complete settling time to generate a valid conversion. 3. DOUT/RDY indicates when a valid conversion is available. 4. The AD7193 selects the next enabled channel and converts on that channel. 5. The user can read the data register while the ADC is performing the conversion on the next channel. The time required to read a valid conversion from all enabled channels is equal to tSETTLE × Number of Enabled Channels For example, if the sinc4 filter is selected, chop is disabled, and zero latency is disabled, the settling time for each channel equals tSETTLE = 4/fADC where fADC is the output data rate when continuously converting on a single channel. Therefore, the time required to read all enabled channels is (4× Number of Enabled Channels)/fADC RDY CONVERSIONS CHANNEL A CHANNEL B 1/fADC CHANNEL C Figure 23. Channel Sequencer DIGITAL INTERFACE As indicated in the On-Chip Registers section, the program- mable functions of the AD7193 are controlled using a set of on-chip registers. Data is written to these registers via the serial interface of the part. Read access to the on-chip registers is also provided by this interface. All communication with the part must start with a write to the communications register. After power-on or reset, the device expects a write to its communications register. The data written to this register determines whether the next operation is a read operation or a write operation, and it determines to which register this read or write operation occurs. Therefore, write access to any of the other registers on the part begins with a write operation to the communications register, followed by a write to the selected register. A read operation from any other register (except when continuous read mode is selected) starts with a write to the communications register, followed by a read operation from the selected register. The serial interface of the AD7193 consists of four signals: CS, DIN, SCLK, and DOUT/RDY. The DIN line is used to transfer data into the on-chip registers and DOUT/RDY is used for accessing data from the on-chip registers. SCLK is the serial clock input for the device, and all data transfers (either on DIN or DOUT/RDY) occur with respect to the SCLK signal. The DOUT/RDY pin also functions as a data ready signal, the line going low when a new data-word is available in the output register. It is reset high when a read operation from the data register is complete. It also goes high prior to the updating of the data register to indicate when not to read from the device, to ensure that a data read is not attempted while the register is being updated. CS is used to select a device. It can be used to decode the AD7193 in systems where several components are connected to the serial bus. Figure 3 and Figure 4 show timing diagrams for interfacing to the AD7193 using CS to decode the part. shows the timing for a read operation from the output shift register of the AD7193, and shows the timing for a write operation to the input shift register. It is possible to read the same word from the data register several times even though the DOUT/ Figure 3 Figure 4 RDY line returns high after the first read operation. However, care must be taken to ensure that the read operations are completed before the next output update occurs. In continuous read mode, the data register can be read only once. The serial interface can operate in 3-wire mode by tying CS low. In this case, the SCLK, DIN, and DOUT/RDY lines are used to communicate with the AD7193. The end of the conversion can be monitored using the RDY bit or pin. This scheme is suitable for interfacing to microcontrollers. If CS is required as a decoding signal, it can be generated from a port pin. For microcontroller interfaces, it is recommended that SCLK idle high between data transfers. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |