5 / 27 page ![]() SE95_7 © NXP B.V. 2009. All rights reserved. Product data sheet Rev. 07 — 2 September 2009 5 of 27 NXP Semiconductors SE95 Ultra high accuracy digital temperature sensor and thermal watchdog In OS interrupt mode, the OS output is used for thermal interruption. When the device is powered-up, the OS output is first activated only when Temp exceeds Tos; then it remains active indefinitely until being reset by a read of any register. Once the OS output has been activated by crossing Tos and then reset, it can be activated again only when Temp drops below Thyst; then again, it remains active indefinitely until being reset by a read of any register. The OS interrupt operation would be continued in this sequence: Tos trip, reset, Thyst trip, reset, Tos trip, reset, Thyst trip, reset, and etc. Putting the device into shutdown mode also resets the OS output. In both cases, comparator mode and interrupt mode, the OS output is activated only if a number of consecutive faults, defined by the device fault queue, has been met. The fault queue is programmable and stored in bits OS_F_QUE[1:0], of register Conf. Also, the OS output active state is selectable as HIGH or LOW by setting accordingly the bit OS_POL of register Conf. At power-up, the device is put into normal operation mode, register Tos is set to 80 °C, register Thyst is set to 75 °C, OS active state is selected LOW and the fault queue is equal to 1. The data reading of register Temp is not available until the first conversion is completed in about 33 ms. The OS response to the temperature is illustrated in Figure 4. (1) OS is reset by either reading register or putting the device in shutdown mode. Assumed that the fault queue is met at each Tos and Thyst crossing point. Fig 4. OS response to temperature 001aad623 (1) (1) (1) Tos Thyst OS RESET OS ACTIVE OS RESET OS ACTIVE OS output in comparator mode OS output in interrupt mode reading temperature limits |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |