Back Button ST7626 Datasheet HTML 51Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 52Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 53Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 54Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 55Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 56Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 57Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 58Page - Sitronix Technology Co., Ltd. ST7626 Datasheet HTML 59Page - Sitronix Technology Co., Ltd. Next Button
Zoom Inzoom in Zoom Outzoom out
 55 / 94 page
background image
ST7626
Ver 1.5
55/94
2007/01/20
Center screen scroll
Top screen scroll
Bottom screen scroll
Whole screen scroll
Fixed area
Scroll area
Since ST7626 processes the liquid crystal display signals on the four-line basis (block basis), FIX and scroll areas are also
specified on the four-line basis (block basis).
DDRAM address corresponding to the top FIX area is set in the block address incrementing direction starting with 0 block.
DDRAM address corresponding to the bottom FIX area is set in the block address decreasing direction starting with 16
st
block. Other DDRAM blocks excluding the top and bottom FIX areas are assigned to the scroll + background areas.
P1: It is used to specify the top block address of the scroll + background areas. Specify the 0
th block for the top screen
scroll or whole screen scroll.
P2: It specifies the bottom address of the scroll+ background areas. Specify the 16
th block for the bottom or whole screen
scroll.
Required relation between the start and end blocks (top block address<bottom block address) must be maintained.
P3: It specifies a specific number of blocks {Numbers of (Top FIX area +Scroll area) block-1}. When the bottom scroll or
whole screens scroll, the value is identical with P2.
You can turn on the area scroll function by executing the area scroll set command first and then specifying the display start
block of the scroll area with the scroll start set command.
[Area Scroll Setup Example]
In the center screen scroll of 1/48 duty (display range: 48 lines = 12 blocks), if 8 lines = 2 blocks and 8 lines = 2 blocks are
specified for the top and bottom FIX areas, 36 lines = 9 blocks is specified for the scroll areas, respectively, 16 lines = 4
blocks on the DDRAM are usable as the background area. Value of each parameter at this time is as shown below.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com