| Electronic Components Datasheet Search |
|
33793 Datasheet(PDF) 21 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
33793 Datasheet(HTML) 21 Page - Freescale Semiconductor, Inc |
|
21 / 27 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 21 33793 FUNCTIONAL DEVICE OPERATION DSI COMMANDS AND RESPONSES REVERSE INITIALIZATION RESPONSE This response message is sent during the next message following a valid Reverse Initialization command to the addressed device. The response is shown in Table 28. Since this is a long-word only command, the short-word response is invalid. No response is generated if the command address field was $0. Table 27. Reverse Initialization Command Format Data Address Command CRC NV BS G1 G0 PA3 PA2 PA1 PA0 A3 A2 A1 A0 1 1 1 1 X3 X2 X1 X0 Legend A[3:0] = Address bits. These bits are the slave address. For programmable devices these bits are all set to zero. For pre- programmed devices these bits contain the pre-programmed address and must match the PA[3:0] bits. G[1:0] = Group bits. These bits are the group number for the slave. These bits are not used by this device and should be set to “0”. PA[3:0] = Program Address bits. These bits are the address that is to be stored into the slave’s address register. NV = Nonvolatile Memory Write. When set to a one, this bit allows a subsequent NVM command to store a nonvolatile address. When set to a zero, NVM programming is disallowed. Once a permanent address has been stored in the device, setting the NV bit to a one has no effect. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the master. Table 28. Reverse Initialization Response Format High Byte Low Byte CRC A3 A2 A1 A0 0 0 0 BF NV BS G1 G0 PA3 PA2 PA1 PA0 X3 X2 X1 X0 Legend A[3:0] = Address bits.The slave address. BF = Bus Fault. BUSIN short to battery detected. BS = Controls closing of the Bus Switch (1=close). G[1:0] = Group bits. Not used on this part, will be set to “0”. The group number programmed into the slave. NV = Nonvolatile Memory Write. The value of the NV bit in the slave. PA[3:0] = Bus Address to set the device to. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the slave. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |