23 / 27 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 23 33793 TYPICAL APPLICATIONS If there is a bus error (due to induced noise or a bus fault), both the master and slave devices will read bad data. The slave reacts to bad data by not sending a response during the next frame. The master will detect a CRC error once it receives the corrupted data sent by the slave, and once again when the slave fails to respond. This is illustrated in Figure 7. When this error occurs, the system software needs to acknowledge this condition and resend a command (any command of same size) so that it can receive the previous response just prior to the bus fault condition (in this case, Command N). Failure to take corrective action will result in unintended errors as shown in Figure 7. In this case, the master will miss Responses N+1 and N+2 and will mistake them for N+3 and N+4. The master should send another N+1 command after the error is acknowledged to re-synchronize the command- response sequence. Figure 7. Bus Traffic With Receive Errors (Master Reads Incorrect Data) POWER UP RESET When power is first applied to the DSI bus, the system must allow enough time for the internal 5.0 volt regulator of each device to come up to a proper level. This implies that H_CAP must charge up to VRECT + 5.0 V, or approximately 6.0 volts. The time this takes is a function of the size of H_CAP, and the current drive of the Master. The following equation can be used to estimate the minimum time to wait before sending an Initialization Command: tMIN ≅ (H_CAP x 6V) / ICHARGE where ICHARGE is the charging current provided by the DSI Master. The above assumes a daisy-chain type of bus topology, and enough time must be allowed for all down-stream devices in the chain to charge up. For example, if device #1 has it’s switch closed after its Initialization Command, then the system must wait for device #2 to power up before sending its Initialization Command, and so on down the line. If the devices are attached in a parallel or point-to-point bus configuration, then the total capacitor value is the sum of all H_CAPS. In addition to the charge up time, enough time must be allocated for the bus fault test (see next section). BUS FAULTS A bus fault is defined as an external voltage on the “Inactive Side” of the Bus Switch that is greater than 3V (typical). Inactive refers to the side of the bus that is not yet connected to the bus. Just before a device is Forward Initialized, the inactive side is defined as BUSOUT. Similarly, just before a device is Reverse Initialized, the BUSIN is defined as the inactive side. The test for a bus fault is only performed once during Forward or Reverse Initialization (when BS bit is set) by applying an 11 mA pull-down current to the inactive side of the Bus Switch and monitoring the voltage. The fault test takes approximately 200 μS. If no fault is detected, the bus switch will be closed, and if a fault is detected, the bus switch will not close. The fault test applies to both programmed and unprogrammed devices. Exception: In the case of a daisy-chain bus topology where the last device BUSOUT line connects to BUSIN of the first device (loop-back), then the fault test will NOT be executed since both BUSIN and BUSOUT are connected to active busses. It is up to the system software to run the appropriate diagnostic tests to resolve this special case. (One alternative is to use a separate DSI Master to handle the loop-back signal path. This second DSI Master is only activated in the case of a bus fault so that the last device can be accessed by means of a reverse initialization.) GLOBAL ADDRESS 0 Any time an Initialization or Reverse Initialization command is sent to the 33793 with an address of 0x0 (global address), the device behaves as follows: • Device initializes to address 0. • Bus switch remains open. This implies that in a daisy- chain bus topology, all devices past the first device will remain off. • NV and BS bits are not stored and have no effect. Command N Bus Error Command N+1 Command N+2 Response N-1 Response N No Response Response N Command N+3 Command N+4 Response N+3 CRC Error CRC Error Error CRC Master Slave Data misinterpreted by Master |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |