MAX6695 Datasheet(PDF) 6 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX6695 Datasheet(HTML) 6 Page - Maxim Integrated Products |
|
6 / 19 page ![]() Detailed Description The MAX6695/MAX6696 are temperature sensors designed to work in conjunction with a microprocessor or other intelligence in temperature monitoring, protec- tion, or control applications. Communication with the MAX6695/MAX6696 occurs through the SMBus serial interface and dedicated alert pins. The overtempera- ture alarms OT1 and OT2 are asserted if the software- programmed temperature thresholds are exceeded. OT1 and OT2 can be connected to a fan, system shut- down, or other thermal-management circuitry. The MAX6695/MAX6696 convert temperatures to digital data continuously at a programmed rate or by selecting a single conversion. At the highest conversion rate, temperature conversion results are stored in the “main” temperature data registers (at addresses 00h and 01h) as 7-bit + sign data with the LSB equal to +1 °C. At slower conversion rates, 3 additional bits are available at addresses 11h and 10h, providing +0.125 °C resolu- tion. See Tables 2, 3, and 4 for data formats. ADC and Multiplexer The MAX6695/MAX6696 averaging ADC (Figure 1) inte- grates over a 62.5ms or 125ms period (each channel, typ), depending on the conversion rate (see Electrical Characteristics table). The use of an averaging ADC attains excellent noise rejection. The MAX6695/MAX6696 multiplexer (Figure 1) automat- ically steers bias currents through the remote and local diodes. The ADC and associated circuitry measure each diode’s forward voltages and compute the tem- perature based on these voltages. If a remote channel is not used, connect DXP_ to DXN. Do not leave DXP_ and DXN unconnected. When a conversion is initiated, all channels are converted whether they are used or not. The DXN input is biased at one VBE above ground by an internal diode to set up the ADC inputs for a dif- ferential measurement. Resistance in series with the remote diode causes about +1/2°C error per ohm. A/D Conversion Sequence A conversion sequence consists of a local temperature measurement and two remote temperature measure- ments. Each time a conversion begins, whether initiat- ed automatically in the free-running autoconvert mode (RUN/STOP = 0) or by writing a one-shot command, all three channels are converted, and the results of the three measurements are available after the end of con- version. Because it is common to require temperature measurements to be made at a faster rate on one of the remote channels than on the other two channels, the conversion sequence is Remote 1, Local, Remote 1, Remote 2. Therefore, the Remote 1 conversion rate is double that of the conversion rate for either of the other two channels. A BUSY status bit in status register 1 (see Table 7 and the Status Byte Functions section) shows that the device is actually performing a new conversion. The results of the previous conversion sequence are always available when the ADC is busy. Remote-Diode Selection The MAX6695/MAX6696 can directly measure the die temperature of CPUs and other ICs that have on-board temperature-sensing diodes (see the Typical Operating Circuit) or they can measure the temperature of a dis- crete diode-connected transistor. Effect of Ideality Factor The accuracy of the remote temperature measurements depends on the ideality factor (n) of the remote “diode” (actually a transistor). The MAX6695/MAX6696 (not the MAX6695Y/MAX6696Y) are optimized for n = 1.008. A thermal diode on the substrate of an IC is normally a PNP with its collector grounded. DXP_ must be connected to the anode (emitter) and DXN must be connected to the cathode (base) of this PNP. If a sense transistor with an ideality factor other than 1.008 is used, the output data will be different from the data obtained with the optimum ideality factor. Fortunately, the difference is predictable. Assume a remote-diode sensor designed for a nominal ideality factor nNOMINAL is used to measure the temperature of a diode with a different ideality factor n1. The measured temperature TM can be corrected using: where temperature is measured in Kelvin and nNOMIMAL for the MAX6695/MAX6696 is 1.008. As an example, assume you want to use the MAX6695 or MAX6696 with a CPU that has an ideality factor of 1.002. If the diode has no series resistance, the mea- sured data is related to the real temperature as follows: For a real temperature of +85°C (358.15K), the measured temperature is +82.87°C (356.02K), an error of -2.13°C. Effect of Series Resistance Series resistance (RS) with a sensing diode contributes additional error. For nominal diode currents of 10μA TT n n T ACTUAL M NOMINAL M =× ⎛ ⎝⎜ ⎞ ⎠⎟ =× ⎛ ⎝ 1 1 008 1 002 . . ⎜⎜ ⎞ ⎠⎟ =× () TM 1 00599 . TT n n M ACTUAL NOMINAL =× ⎛ ⎝⎜ ⎞ ⎠⎟ 1 Dual Remote/Local Temperature Sensors with SMBus Serial Interface 6 _______________________________________________________________________________________ |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |