18 / 32 page ![]() TLE6288R SPI Data Sheet 18 Rev. 2.5, 2010-10-11 Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal function. Overload, Shorted Load or Overtemperature: HL is set when the current limitation gets active, i.e. there is a overload, short to supply or overtemperature condition. The second reason for this bit combination is overtemperature of the corresponding channel. In current regulation mode HL is also set if the load current reaches the programmed current value in a time shorter than the fixed off time ( t fo). This detection is only performed at the first rising load current edge after a channel is turned on (for channel 1 to 3). See Chapter 7.3. Open load: LH is set when open load is detected (in off state of the channel). Switch Bypassed: • Short to GND: in lowside configuration LL is set when this condition is detected. • Short to Battery: in highside configuration LL is set when this condition is detected. Channel Overtemperature Flag: In case of overtemperature in any output channel in on state the overtemperature Flag in the SPI diagnosis register is set (change bit 3 from 0 to 1). This bit can be used to distinguish between Overload and Overtemperature (both HL combination) and is reset by switching OFF/ON the affected channel. In addition the DIAG6 / Overtemp pin is set low (if configured as Overtemp Flag). IC Overtemperature Flag: When the IC logic temperature exceeds typ. 170 °C the non-latching IC Overtemperature Flag will be set in the SPI diagnosis register (change bit 2 from 0 to 1). In addition the DIAG6 / Overtemp pin is set low (if configured as Overtemp. Flag). 5.4 SPI Commands, Values and Parameters The 16-bit SPI is used to program different IC functions and values, turn on and off the channels and to get detailed diagnosis information. Therefore 4 command bits and 12 data bits are used. Figure 10 SI SO CS 4 Bits 12 Bits Command Da ta Diagnosis (Ch. 1 to 6) + 2 Temp. Flags SI command : 4 Command Bits program the operation mode of Channels 1 to 6. 12 Data Bits configure the device and give the input information (on or off) for Channel 1 to 6. SO diagnosis 16 bit diagnosis information (two bit per channel) of channels 1 to 6 plus two Overtemperature Flags |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |