33 / 56 page ![]() AD9979 Rev. C | Page 33 of 56 SHA Mode—Differential Input Configuration In this configuration, which uses a differential input sample- and- hold amplifier (SHA), a signal is applied to the CCDINP input, while an inverse signal is applied simultaneously to the CCDINM input (see Figure 47). Sampling occurs on both signals at the same time, creating the differential output for amplification and for the ADC (see Figure 48 and Table 20). IMAGE SENSOR SHA/ CDS CCDINM CCDINP AD9979 Figure 47. SHA Mode—Differential Input Configuration (N + 1) SIGNAL SAMPLE (N) SIGNAL SAMPLE POSITIVE INPUT NEGATIVE INPUT PEAK SIGNAL LEVEL (VFS) BLACK SIGNAL LEVEL (VBLK) MINIMUM SIGNAL LEVEL (VMIN) GND Figure 48. SHA Mode—Differential Input Signal Table 20. SHA Mode—Differential Voltage Levels Signal Level Symbol Min Typ Max Unit Black Signal Level VBLK 0 mV Saturation Signal Level VFS 1000 VDD − 300 1400 mV Minimum Signal Level VMIN 0 1800 mV SHA Mode—DC-Coupled, Single-Ended Input The SHA mode can also be used in a single-ended fashion, with the signal from the image sensor applied to the CDS/SHA using a single input, CCDINP. This is similar to the differential configuration, except in this case, the CCDINM line is held at a constant dc voltage. This establishes a reference level that matches the image sensor reference voltage (see Figure 49). Referring to Figure 50 and Table 21, the CCDINM signal is a constant dc voltage set at a level above ground potential. The sensor signal is applied to the other input, and samples are taken at the signal minimum and at a point of signal maximum. The resulting differential signal is the difference between the signal and the reference voltage. IMAGE SENSOR SHA/ CDS CCDINM CCDINP AD9979 NOTES 1. DC VOLTAGE ABOVE GROUND CAN BE USED TO MATCH THE SENSOR REFERENCE LEVEL. Figure 49. SHA Mode—DC-Coupled, Single-Ended Input Configuration (N + 1) SIGNAL SAMPLE (N) SIGNAL SAMPLE POSITIVE INPUT NEGATIVE INPUT PEAK SIGNAL LEVEL (VFS) BLACK SIGNAL LEVEL (VBLK) MINIMUM SIGNAL LEVEL (VMIN) GND Figure 50. SHA Mode—DC-Coupled, Single-Ended Input Signal Table 21. SHA Mode—Single-Ended, Input Voltage Levels Signal Level Symbol Min Typ Max Unit Black Signal Level VBLK 0 mV Saturation Signal Level VFS 1000 1400 mV Minimum Signal Level VMIN 0 mV CDS Timing Control The timing shown in Figure 19 illustrates how the two internally generated CDS clocks, SHP and SHD, are used to sample the reference level and the data level of the CCD signal, respectively. The placement of the SHP and SHD sampling edges is determined by the setting of SHPLOC and SHDLOC, located at Address 0x36. Placement of these two clock signals is critical in achieving the best performance from the CCD. SHA Timing Control When SHA mode is selected, only the SHPLOC setting is used to sample the input signal, but the SHDLOC signal still needs to be programmed to an edge setting of SHPLOC + 32. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |