29 / 56 page ![]() AD9979 Rev. C | Page 29 of 56 Single-Field Toggles Single-field toggles begin in the field following the register write. There can be up to two toggles in the field. The mode is set with GPx_PROTOCOL equal to 1. In this mode, the field toggle settings must be set to 1. Toggles repeat for each field until GPx_PROTOCOL is set to 0. GPx_PROTOCOL must be reset to 0 for one field before it can be active again. Preparation The GP toggle positions can be programmed any time prior to use. For example, 0x054 ← 0x000A001 0x055 ← 0x0002000 0x056 ← 0x000000F Details A) Field 0: 0x052 ← 0x0000001 B) Field 1: 0x052 ← 0x0000000 VD 1 REG WRITE AB GP1_PROTOCOL 0 1 0 GPO1 NOTES 1. THE FIELD TOGGLE POSITION IS IGNORED WHEN THE GPO PROTOCOL IS 1. TOGGLE POSITIONS REPEAT FOR EACH FIELD UNTIL GPO PROTOCOL IS RESET. 2 Figure 36. Single-Field Toggles Using GP1_PROTOCOL = 1 Scheduled Toggles Scheduled toggles are programmed to occur during any upcoming field. For example, there can be one toggle in Field 1 and the next toggle in Field 3. The mode is set with GPx_PROTOCOL = 2, which tells the GPO to obey the primary field counter. Preparation The GP toggle positions can be programmed any time prior to use. For example, 0x054 ← 0x00C4002 0x055 ← 0x0004000 0x056 ← 0x00000B3 Details A) Field 0: 0x050 ← 0x0000001 0x052 ← 0x0000002 VD 1 2 REG WRITE A GP1_PROTOCOL 0 PRIMARY COUNT 01 2 0 GPO1 THE PRIMARY COUNTER REGULATES THE SUBCK AND VSG ACTIVITY. LINK A GPO TO THE PRIMARY COUNTER ONLY IF IT IS TO HAPPEN DURING EXPOSURE/READ. (IDLE) 2 Figure 37. Scheduled Toggles Using GP1_PROTOCOL = 2 RapidShot Sequences RapidShot technology provides continuous repetition of scheduled toggles. As in the case of scheduled toggles, a pulse can traverse multiple fields. The mode is set with GPx_PROTOCOL = 3, which tells the GPO to obey the repeating primary field counter. GPx_PROTOCOL must be reset to 0 for one field before it can be active again. Preparation The GPO toggle positions can be programmed any time prior to use. For example, 0x051 ← 0x0000002 0x054 ← 0x000A001 0x055 ← 0x0004000 0x056 ← 0x000000F 0x052 ← 0x0000003 Details A) Field 0: 0x050 ← 0x0000002 B) Field 2: 0x050 ← 0x0000007 VD 1 234 5 REG WRITE AB GP1_PROTOCOL 03 0 (IDLE) 1 2 12 10 GPO1 TERMINATED AT VD EDGE NOTES 1. THE GPO PROTOCOLS ARE THE SAME AS THE SCHEDULED TOGGLES, EXCEPT THE TOGGLES CAN BE EXCLUDED FROM REPETITION BY CHOOSING GPO PROTOCOL 2. CAUTION! THE FIELD COUNTER MUST BE FORCED INTO IDLE STATE TO TERMINATE REPETITIONS. PRIMARY COUNT Figure 38. RapidShot Toggle Operation Using GP1_PROTOCOL = 3 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |