30 / 56 page ![]() AD9979 Rev. C | Page 30 of 56 ShotTimer Sequences ShotTimer technology provides internal delay of scheduled toggles. The delay is in terms of fields. Preparation The GP toggle positions can be programmed any time prior to use. For example, 0x051 ← 0x0000032 0x054 ← 0x000A001 0x055 ← 0x0004000 0x056 ← 0x000000F 0x052 ← 0x0000002 Details A) Field 0: 0x050 ← 0x0000003 VD 45 REG WRITE A GP1_PROTOCOL 03 0 (IDLE) 1 23120 GPO1 PRIMARY COUNT 123 Figure 39. ShotDelay Toggle Operation Using GP1_PROTOCOL = 3 GP LOOK-UP TABLES (LUT) The AD9979 includes a LUT for each pair of consecutive GP signals when configured as outputs. The external GPO outputs from the GPO1 pair can output the result of the LUT or the original GPO internal signal. GP1_INT LUT 1 0 0 1 GPO2 GPO1 GP2_INT GP_LUT_EN [9] GP_LUT_EN [8] Figure 40. Internal LUT for GPO1 and GPO2 Signals Address 0x52 dictates the behavior of the LUT and identifies which signals receive the result. Each 4-bit register can realize any logic combination of GPO1 and GPO2. Table 17 shows how the register values of GP12_LUT[13:10] are determined. XOR, NAND, AND, and OR results are shown, but any 4-bit combination is possible. A simple example of XOR gating is shown in Figure 41. Table 17. LUT Results Based on GPO1, GPO2 Values GPO2 GPO1 LUT XOR NAND AND OR 0 0 0 1 0 0 0 1 1 1 0 1 1 0 1 1 0 1 1 1 0 0 1 1 GP1_INT GP2_INT GPO2 LOGIC COMBINATION (XOR) OF PROGRAMMED TOGGLES GPO1 AND GPO2. GP12_LUT = 0x6 GP_LUT_EN = 0x2 GPO1 Figure 41. LUT Example for GPO1 XOR GPO2 Field Counter and GPO Limitations 1. The following is a summary of the known limitations of the field counters and GPO signals that dictate usability. 2. The field counter trigger (Address 0x50) is self-reset at the start of every VD period. Therefore, there must be one VD period between sequential programming to that address. 3. If the protocol is set to 1, the toggles repeat for each field until the protocol is set to idle. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |