54 / 112 page ![]() 54 Am186TMER and Am188TMER Microcontrollers Data Sheet DRAF T If the code crashes or hangs, the TIMER1 countdown will cause a watchdog interrupt. Timer 2 is not connected to any external pins. It can be used for real-time coding and time-delay applications. It can also be used as a prescale to timers 0 and 1, or as a DMA request source. The timers are controlled by eleven 16-bit registers in the peripheral control block. A timer’s timer-count reg- ister contains the current value of that timer. The timer- count register can be read or written with a value at any time, whether the timer is running or not. The microcon- troller increments the value of the timer-count register each time a timer event occurs. Each timer also has a maximum-count register that de- fines the maximum value the timer will reach. When the timer reaches the maximum value, it resets to 0 during the same clock cycle—the value in the maximum-count register is never stored in the timer-count register. Also, timers 0 and 1 have a secondary maximum-count reg- ister. Using both the primary and secondary maximum- count registers lets the timer alternate between two maximum values. If the timer is programmed to use only the primary max- imum-count register, the timer output pin switches Low for one clock cycle after the maximum value is reached. If the timer is programmed to use both of its maximum- count registers, the output pin indicates which maxi- mum-count register is currently in control, thereby cre- ating a waveform. The duty cycle of the waveform depends on the values in the maximum-count regis- ters. Each timer is serviced every fourth clock cycle, so a timer can operate at a speed of up to one-quarter the internal clock frequency. A timer can be clocked exter- nally at this same frequency; however, because of in- ternal synchronization and pipelining of the timer circuitry, the timer output may take up to six clock cy- cles to respond to the clock or gate input. WATCHDOG TIMER The Am186ER/Am188ER microcontrollers provide a hardware watchdog timer. The Watchdog Timer (WDT) can be used to regain control of the system when soft- ware fails to respond as expected. The WDT is inactive after reset. It can be modified only once by a keyed se- quence of writes to the Watchdog Timer Control Regis- ter (WDTCON) following reset. This single write can either disable the timer or modify the timeout period and the action taken upon timeout. A keyed sequence is also required to reset the current WDT count. This behavior ensures that randomly executing code will not prevent a WDT event from occurring. The WDT supports up to a 1.34-second timeout period in a 50-MHz system. The WDT can be configured to cause either an NMI in- terrupt or a system reset upon timeout. If the WDT is configured for NMI, the NMIFLAG in the WDTCON Register is set when the NMI is generated. The NMI in- terrupt service routine (ISR) should examine this flag to determine if the interrupt was generated by the WDT or by an external source. If the NMIFLAG is set, the ISR should clear the flag by writing the correct keyed se- quence to the WDTCON Register. If the NMIFLAG is set when a second WDT timeout occurs, a WDT sys- tem reset is generated rather than a second NMI event. When the processor takes a WDT reset, either be- cause of a single WDT event with the WDT configured to generate resets or due to a WDT event with the NMI- FLAG set, the RSTFLAG in the WDTCON Register is set. This allows system initialization code to differenti- ate between a hardware reset and a WDT reset and take appropriate action. The RSTFLAG is cleared when the WDTCON Register is read or written. The processor does not resample external pins during a WDT reset. This means that the clocking, the Reset Configuration Register, and any other features that are user-selectable during reset do not change when a WDT system reset occurs. PIO Mode and PIO Direc- tion registers are not affected and PIO data is unde- fined. All other activities are identical to those of a normal system reset. Note: The Watchdog Timer (WDT) is inactive after reset. DIRECT MEMORY ACCESS Direct memory access (DMA) permits transfer of data between memory and peripherals without CPU involve- ment. The DMA unit in the Am186ER and Am188ER microcontrollers, shown in Figure 13, provides two high-speed DMA channels. Data transfers can occur between memory and I/O spaces (e.g., memory to I/O) or within the same space (e.g., memory-to-memory or I/O-to-I/O). Additionally, bytes (also words on the Am186ER microcontroller) can be transferred to or from even or odd addresses. Only two bus cycles (a minimum of eight clocks) are necessary for each data transfer. Each channel accepts a DMA request from one of the four sources: the channel request pin (DRQ1–DRQ0), Timer 2, a serial port, or system software. The two DMA channels can be programmed with different prior- ities to resolve simultaneous DMA requests, and trans- fers on one channel can interrupt the other channel. The DMA channels can be directly connected to the asynchronous serial port. DMA and serial port transfer is accomplished by programming the DMA controller to perform transfers between a data source in memory or I/O space and a serial port transmit or receive register. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |