| Electronic Components Datasheet Search |
|
AD9851FSPCB Datasheet(PDF) 14 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9851FSPCB Datasheet(HTML) 14 Page - Analog Devices |
|
14 / 24 page ![]() AD9851 –14– the factory test mode. Exit from serial mode to parallel mode is only possible using the RESET command. The function assignments of the data and control words are shown in Tables I and III; the detailed timing sequence for updating the output frequency and/or phase, resetting the device, engaging the 6 REFCLK multiplier, and powering up/down, are shown in the timing diagrams of Figures 13 through 20. As a programming example for the following DDS characteristics: 1. Phase set to 11.25° 2. 6 REFCLK multiplier engaged 3. Powered-up mode selected 4. Output = 10 MHz (for 180 MHz system clock) In parallel mode, user would program the 40-bit control word (composed of five 8-bit loads) as follows: W0 = 00001001 W1 = 00001110 W2 = 00111000 W3 = 11100011 W4 = 10001110 If in serial mode, load the 40 bits starting from the LSB location of W4 in the above array, loading from right to left, and ending with the MSB of W0. Table I. 8-Bit Parallel-Load Data/Control Word Functional Assignment Word Data[7] Data[6] Data[5] Data[4] Data[3] Data[2] Data[1] Data[0] W0 Phase–b4 (MSB) Phase–b3 Phase–b2 Phase–b1 Phase–b0 (LSB) Power-Down Logic 0* 6 REFCLK Multiplier Enable W1 Freq–b31 (MSB) Freq–b30 Freq–b29 Freq–b28 Freq–b27 Freq–b26 Freq–b25 Freq–b24 W2 Freq–b23 Freq–b22 Freq–b21 Freq–b20 Freq–b19 Freq–b18 Freq–b17 Freq–b16 W3 Freq–b15 Freq–b14 Freq–b13 Freq–b12 Freq–b11 Freq–b10 Freq–b9 Freq–b8 W4 Freq–b7 Freq–b6 Freq–b5 Freq–b4 Freq–b3 Freq–b2 Freq–b1 Freq–b0 (LSB) *This bit is always Logic 0 unless invoking the serial mode (see Figure 17). After serial mode is entered, this data bit must be set back to Logic 0 for proper operation. W0* W1 W2 W3 W4 tCD tDH tDS tWL tWH tFD ttttttFH FH FH FH FH tttttFL FL FL FL FL *OUTPUT UPDATE CAN OCCUR AFTER ANY WORD LOAD AND IS ASYNCHRONOUS WITH REFERENCE CLOCK tttttCF CF CF CF CF CF VALID DATA SYSCLK DATA W CLK FQ UD AOUT Figure 13. Parallel Load Frequency/Phase UpdateTiming Sequence Note:To update W0 it is not necessary to load W1 through W4. Simply load W0 and assert FQ_UD.To update W1, reload W0 then W1— users do not have random access to programming words. Table II. Timing Specifications Symbol Definition Min tDS Data Setup Time 3.5 ns tDH Data Hold Time 3.5 ns tWH W_CLK High 3.5 ns tWL W_CLK Low 3.5 ns tCD REFCLK Delay after FQ_UD 3.5 ns* tFH FQ_UD High 7.0 ns tFL FQ_UD Low 7.0 ns tFD FQ_UD Delay after W_CLK 7.0 ns tCF Output Latency from FQ_UD Frequency Change 18 SYSCLK Cycles Phase Change 13 SYSCLK Cycles *Specification does not apply when the 6 REFCLK multiplier is engaged. REV. D |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |