| Electronic Components Datasheet Search |
|
LD1960 Datasheet(PDF) 13 Page - LDT Co., Ltd |
|
|
|||||||||||||||||||||||||||||
LD1960 Datasheet(HTML) 13 Page - LDT Co., Ltd |
|
13 / 23 page ![]() Ver1.0 13 LD1960 9 SEGMENT X 7 GRID LED Driver with key scan COMMAND 4 : DISPLAY CONTROL COMMANDS The Display Control Commands are used to turn ON or OFF a display. It is also used to set the pulse width. Please refer to the diagram below. When the power is turned ON, a 1/16 pulse width is selected and the display is turned OFF. MSB b7 LSB b6 b5 b4 b3 b2 b1 b0 Don’t Care Dimming Quantity Settings : 000 : Pulse width = 1/16 001 : Pulse width = 2/16 010 : Pulse width = 4/16 011 : Pulse width = 10/16 100 : Pulse width = 11/16 101 : Pulse width = 12/16 110 : Pulse width = 13/16 111 : Pulse width = 14/16 Display Settings : 0 : Display OFF 1 : Display ON 10 : COMMAND 4 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|