Back Button ICLS602X Datasheet HTML 10Page - Infineon Technologies AG ICLS602X Datasheet HTML 11Page - Infineon Technologies AG ICLS602X Datasheet HTML 12Page - Infineon Technologies AG ICLS602X Datasheet HTML 13Page - Infineon Technologies AG ICLS602X Datasheet HTML 14Page - Infineon Technologies AG ICLS602X Datasheet HTML 15Page - Infineon Technologies AG ICLS602X Datasheet HTML 16Page - Infineon Technologies AG ICLS602X Datasheet HTML 17Page - Infineon Technologies AG ICLS602X Datasheet HTML 18Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 33 page
background image
LED System Driver ICs
ICLS6x Series
Functional Description
Data Sheet
14
Version 1.0, 2011-05-19
3.2
Power Management
Figure 5
Power management of ICLS6x Series controllers
The undervoltage lockout function monitors the external supply voltage VVCC. When the LED drive is connected to
the main line, the internal startup cell is biased and starts to charge the external capacitor CVCC, which is connected
to the VCC pin. The VCC charge current that is provided by the startup cell from the drain pin is 1.05 mA. If VVCC
exceeds the on-threshold VCCon (= 18 V), the bias circuit is switched on. Then the startup cell is switched off by the
undervoltage lockout; therefore no power losses are present due to the connection of the startup cell to the drain
voltage. An hysteresis loop is implemented to avoid uncontrolled ringing at switch-on. Switch-off of the controller
can only take place after the active mode has been entered and VVCC has fallen below 10.3 V.
The maximum current consumption before the controller is activated is about 300 µA.
If VVCC falls below the off-threshold VCCoff (= 10.3 V), the bias circuit is switched off and a power-down reset causes
discharging of the soft-start capacitor CSoftS at pin SoftS via T4 (see Figure 5). This ensures in every startup cycle
that the voltage ramp at the SoftS pin starts at zero.
The bias circuit is switched off if Auto Restart mode is entered. The current consumption is then reduced to 300 µA.
Once the malfunction condition is resolved, this block will then turn back on. The recovery from Auto Restart mode
does not require disconnection of the LED drive from the AC line.
Internal Bias
Voltage
Reference
Power Management
5V
VCC
Undervoltage Lockout
18V
10.3
T1
Power -Down Reset
SoftS
Auto Restart
Mode
Startup Cell
Drain



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com