12 / 30 page ![]() 12 Interrupt Servicing Register R(1) is always used as the program counter when- ever interrupt servicing is initialized. When an interrupt request occurs and the interrupt is allowed by the program (again, nothing takes place until the completion of the cur- rent instruction), the contents of the X and P registers are stored in the temporary Register T, and X and P are set to new values; hex digit 2 in X and hex digit 1 in P. Master Inter- rupt Enable is automatically deactivated to inhibit further interrupts. The user’s interrupt routine is now in control; the contents of T may be saved by means of a single SAV instruction (78) in the memory location pointed to by R(X) or the contents of T, D, and DF may be saved using a single DSAV instruction (6876). At the conclusion of the interrupt, the user's routine may restore the pre-interrupted value of X and P with either a RET instruction (70) which permits fur- ther interrupts, or a DlS instruction (71), which disables fur- ther interrupts. Interrupt Generation and Arbitration (See Figure 6) Interrupt requests can be generated from the following sources: 1. Externally through the interrupt input (request not latched). 2. Internally due to Counter/Timer response (request is latched). a. On the transition from count (01)16 to its next value (counter underflow). b. On the transition of EF1 in pulse measurement mode 1. c. On the transition of EF2 in pulse measurement mode 2. For an interrupt to be serviced by the CPU, the appropriate Interrupt Enable flip-flops must be set. Thus, the External Interrupt Enable flip-flop must be set to service an external interrupt request, and the Counter Interrupt Enable flip-flop must be set to service an internal Counter/Timer interrupt request. In addition, the Master interrupt Enable flip-flop (as used in the CDP1802) must be set to service either type of request. All 3 flip-flops are initially enabled with the applica- tion of a hardware reset, and, can be selectively enabled or disabled with software: ClE, ClD instructions for the ClE flip- flop; XlE, XlD instructions for the XIE flip-flop; RET, DIS instructions for the MIE flip flop. Short branch instructions on Counter Interrupt (BCI) and External Interrupt (BXl) can be placed in the user's interrupt service routine to provide a means of identifying and priori- tizing the interrupt source. Note, however, that since the External Interrupt request is not latched, it must remain active until the short branch is executed if this priority arbitra- tion scheme is used. Interrupt requests can also be polled if automatic interrupt service is not desired (MlE = 0). With the Counter Interrupt and External Interrupt short branch instructions, the branch will be taken if an interrupt request is pending, regardless of the state of any of the 3 Interrupt Enable flip-flops. The latched counter interrupt request signal will be reset when the branch is taken, when the CPU is reset, or with a LDC instruction with the Counter stopped. Note, that exiting a counter-initiated interrupt routine without resetting the counter-interrupt latch will result in immediately reentering the interrupt routine. Counter/Timer and Controls (See Figure 7) This logic consists of a presettable 8-Bit down-counter (Mod- ulo N type), and a conditional divide-by-32 prescaler. After counting down to (01)16the counter returns to its initial value at the next count and sets the Counter Interrupt Latch. It will continue decrementing on subsequent counts. If the counter is preset to (00)16 full 256 counts will occur. During a Load Counter instruction (LDC) if the counter was stopped with a STPC Instruction, the counter and its holding register (CH) are loaded with the value in the D Register and any previous counter interrupt is cleared. If the LDC is exe- cuted when the counter is running, the contents of the D Register are loaded into the holding register (CH) only and any previous counter interrupt is not cleared. (LDC RESETS the Counter Interrupt Latch only when the Counter is stopped). After counting down to (01)16 the next count will load the new initial value into the counter, set the Counter Interrupt Latch, and operation will continue. CDP1805AC, CDP1806AC |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |