7 / 16 page ![]() 7 LT1306 OPERATIO The LT1306 is a fixed frequency current mode PWM regulator with integrated power transistor Q1 and syn- chronous rectifier Q2. In the Block Diagram, Figure 2, the PWM control circuit is enclosed within the dashed line. It consists of the current sense amplifier (A2), the oscillator, the compen- sating ramp generator, the PWM comparator (A4), the logic (X1 and X2), the power transistor driver (X4) and the main power switch (Q1). Notice that the clock (CLK) “blanks” Q1 conduction. The internal oscillator frequency is 300kHz. The pulse width of the clock determines the maximum on duty ratio of Q1. In the LT1306 this is set to 88%. Q1 turns on at the trailing edge of the clock pulse. To prevent subharmonic oscillation above 50% duty ratio, a com- pensating ramp (generated from the oscillator sawtooth) is added to the sensed Q1 current. Q1 is turned off when this sum exceeds the error amplifier A1 output, VC. Q1’s absolute current limit is reached when VC’s upward excursion is clamped internally at 1.28V. The error amplifier output, VC, determines the peak switch current required to regulate the output voltage. VC is a measure of the output power. At heavy loads, the average and the peak inductor currents are both high. VC moves to the upper end of its operating range and the LT1306 oper- ates in continuous conduction mode (CCM). As load decreases, the average inductor current de- creases. In CCM, the peak-to-peak inductor current ripple to the first order depends only on the inductance, the input and the output voltages. When the average inductor current falls below 1/2 of the peak-to-peak inductor current ripple, the converter enters discontinuous con- duction mode (DCM). The switching frequency remains constant except that the inductor current always returns to zero within each switching cycle. In both CCM and DCM, the output voltage is regulated with negative feedback. A1 amplifies the error voltage between the internally generated 1.24V reference and the attenuated output voltage. The RC network from the VC pin to ground provides the loop compensation. Further reduction in the load moves VC towards the lower end of its operating range. Both the peak inductor current and switch Q1’s on-time decrease. Hysteretic comparator A3 determines if VC is too low for the LT1306 to operate efficiently. As VC falls below the trip voltage VB, the output of A3 goes high. All circuits except the error amplifier, comparators A3 and A5, and the rectifier driver control X5, are turned off. After the remaining energy stored in the inductor is delivered to the output through the synchro- nous rectifier Q2, the LT1306 stops switching. In this idle state, the LT1306 draws only 160 µA from the input. With switching stopped and the load being powered by the output filter capacitor, the output voltage decreases. VC then starts to increase. Q1 does not start to switch until VC rises above the upper trip point of A3. The LT1306 again delivers power to the output as a current mode PWM converter except that the switch current limit is only about 250mA due to the low value of VC. If the load is still light, the output voltage will rise and VC will fall, causing the converter to idle again. Power delivery therefore occurs in bursts. The on-off cycle frequency, or burst frequency, depends on the operating conditions, the inductance and the output filter capacitance. The output voltage ripple in Burst Mode operation is usually higher than either CCM or DCM operation. Burst Mode operation increases light load efficiency because it delivers more energy to the output during each clock cycle than is possible with DCM operation’s extremely low peak switch current. This al- lows fewer switching cycles per unit time to maintain a given output. Chip supply current therefore becomes a small fraction of the total input current. The synchronous rectifier is represented as NPN transis- tor, Q2, in the Block Diagram (Figure 2). A rectifier drive circuit, X5, supplies variable base drive to Q2 and controls the voltage across the rectifier. The supply voltage, VCAP, for the driver is generated locally with the bootstrap cir- cuit, D1 and C1 (Figure 1). When Q1 is on, the bootstrap capacitor C1 is charged from the input to the voltage VIN – VD1(ON) – VCESAT1. The charging current flows from the input through D1, C1 and Q1 to ground. After Q1 is switched off, the node SW goes above VO by the rectifier drop VCESAT2. D1 becomes back-biased and the CAP volt- age is pushed up to VO + VCESAT2 + VIN – VD1(ON) – VCESAT1. C1 supplies the base drive to Q2. The consumed charge is replenished during the Q1 on interval. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |