| Electronic Components Datasheet Search |
|
TLE6240GP Datasheet(PDF) 11 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE6240GP Datasheet(HTML) 11 Page - Infineon Technologies AG |
|
11 / 23 page ![]() Data Sheet TLE 6240 GP V3.1 Page 26.Aug 2002 11 In the following section the different control bytes will be descriped. X used within the control byte means: X = L: Command is valid for channels 1 to 8 X = H: Command is valid for channels 9 to 16 1/6. LLLL XXXX - Diagnosis only By clocking in this control byte, it is possible to get pure diagnostic information (two bits per channel) in accordance with Figure 1 (page 14). The data bits are ignored, so that the state of the outputs are not influenced. This command is only active once unless the next control command is again "Diagnosis only". Diagnostic information can be read out at any time with no change of the switching conditions. Example for two consecutive chip select cycles: SI LLLL LLLL XXXX XXXX SO HHHH HHHH HHHH HHHH CS SI command: Diagnosis only for channels 1 to 8. No change of the output states SO diagnosis: No fault, normal function of channels 1 to 8 or 9 to 16 depending on previous SI command SI LLLL HHHH XXXX X XXX SO CS SI command: Diagnosis only for channels 9 to 16. No change of the output states DIAG_2 provided during next chip select cycle SO diagnosis: 2 bit diagnosis performed for channels 1 to 8 DIAG_1 2/7. HHLL XXXX - Reading back of the eight inputs and ‘1-bit Diagnosis’ provided If the TLE 6240 GP is used as bare die in a hybrid application, it is necessary to know if proper connections exist between the µC-port and parallel inputs. By entering ‘HHLL’ as the control word, the first eight bits of the SO give the state of the parallel inputs, depending on the µC signals. By comparing the IN-bits with the corresponding µC-port signal, the necessary con- nection between the µC and the TLE 6240 GP can be verified - i.e. ‘read back of the inputs’. The second 8-bits fed out at the serial output contains ‘1-bit’ fault information of the outputs (H = no fault, L = fault ). In the expression given below for the output byte, ‘FX’ is the fault bit for channel X. MSB LSB IN12 IN11 IN10 IN9 IN4 IN3 IN2 IN1 Parallel Input Signals """""""" "! """"""""" FX FX FX FX FX FX FX FX Fault Bits Channels 1 to 8 or 9 to 16 """""""! """"""" : Serial Output byte |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |